EN
www.magmaweld.com
27
USER MANUAL | KULLANIM KILAVUZU
ID 300 M/MW - ID 400 M/MW - ID 500 M/MW
Maintenance And Failure Information
4.3 Troubleshooting
The following tables contain possible errors to be encountered and their solutions.
Machine is not operating
• Contact the authorized service.
• Replace the contact nozzle.
• Set the correct pressure wheel setting.
• Change your voltage and wire speed settings.
• Contact the authorized service.
• Contact the authorized service.
• Check the gas used and its setting. If the gas
cannot be adjusted, consult the authorized
service.
• Contact the authorized service.
• Problematic electrical connection in the machine
• Make sure the machine is connected to the
mains.
• The power supply fuses, mains cable or plug
are problematic or damaged
• The pressure on the wire feed rollers is too
• Check the power supply fuses, mains cable
and plug.
• Set the correct pressure wheel setting.
• The mains connections are not correct
• Wire feed rollers were not chosen to fit the
wire diameter.
• Check whether the mains connections are
correct.
• Select the appropriate wire feed roller.
• Electronic card failure
• The pressure of the reels is not enough.
• Contact nozzle size was selected incorrectly
or is damaged.
• The welding parameters have not been
• Electronic card failure
• Electronic card failure
• The protecting gas flows too much or too
little.
• Electronic card failure
• The on/off switch does not operate correctly
• Check the on/off switch.
Wire feed motor failure.
The wire feed motor is operating,
but the wire is not moving further.
Fan is not operating
No good welding.
Unstable and/or non-adjustable
welding current
Failure
Reason
Solution
4.4 Error Codes
Err 01 :
Err 02 :
Err 03 :
Err 04 :
Err 05 :
Err 06 :
Canbus Error
Over Temperature Error
Over Current Error
Low Mains Voltage
NTC Error
High Mains Voltage