EN
www.magmaweld.com
16
USER MANUAL | KULLANIM KILAVUZU
ID 300 M/MW - ID 400 M/MW - ID 500 M/MW
1.4 Technical Data
TECHNICAL DATA
Line Voltage (3 faz - 50-60 Hz)
Open Circuit Voltage
Input Power (%40) MMA
Weight
Protection Class
Input Power (%40) TIG
Rated Welding Current
Input Current (%40) MMA
Drive Roll Size (V socket)
Input Current (%40) TIG
Dimensions (UxGxY)
Welding Current Range
Wire Feding Speed
UNIT
V
ADC
kVA
kVA
A
mm
mm
m/dk
ADC
A
kg
V
ID 300 M / MW
400
62
102
IP21S
15.1
300
0.8 - 1.2
21.9
1070x530x1360
50 - 300
1 - 21.5
ID 400 M / MW
400
82
24,5
112
22,6
400
35,5
0.8 - 1.6
32,7
1070x530x1360
50 - 400
1 - 21.5
ID 500 M / MW
400
82
33.4
114
32.7
500
48.3
0.8 - 1.6
47.5
1070x530x1360
50 - 500
1 - 21.5
ID 300 M / MW - ID 400 M / MW STANDARD ACCESSORIES
ID 500 M / MW STANDARD ACCESSORIES
OPTIONAL ACCESSORIES
Electrode Holder and Cable 35mm2/5m
Electrode Holder and Cable 95mm2/5m
Torch
CO2/ Ar Pressure Regulator
CO2 Heater
QTY
QTY
QTY
1
1
1
1
1
PRODUCT CODE
PRODUCT CODE
PRODUCT CODE
K301100405
K301100705
S520023203
S520001005
S520009003
1.5 Accessories
Technical Information
As defined in the standard EN 60974-1, the operating cycle rate includes a time period of 10 minutes. For example, if a machine specified as 250A
at %60 is to be operated at 250A, the machine can weld without interruption in the firs 6 minutes of the 10 minute period(zone 1). However, the
following 4 minutes should be kept idle for the machine cool down (zone 2).