ID 250TW DC PULSE / ID 300TW DC PULSE
EN
www.magmaweld.com
20
USER MANUAL | KULLANIM KILAVUZU
DC - PULSE DC
For using welding modes 2 Stroke - 4 Stroke - Spot Welding in Flat DC mode, select Flat DC mode by button. İts led will be on. In this mode, only main
current. İs used and it is simply adjusted by the multifunctional knob. For using welding modes 2 Stroke - 4 Stroke - Spot Welding in Pulse DC mode,
select Pulse DC mode by button. İts led will be on. In this case, main current, base current and the Pulse frequency should be adjusted by the multifun-
ction knob. Welding current changes between main current and base current in the adjusted Pulse frequency.
Recommended TIG
Welding Current “A”
Electrode
Diameter “mm”
30-130
45-180
70-240
1.6
2.0
2.4
3.3.3 MMA Welding Process
Push the welding mode selection button. For selecting the MMA welding mode. Stick electrode welding LED lights.
Adjust the current via current adjustment knob. Below table can be used as a rough referance for mild steel electrodes. For exact parameters, please
refer to the electrode manufacturer recommendations.
Type Diameter
“mm”
Recommended Welding Current
Rutile
2.0
2.5
3.25
4.0
5.0
40-60 A
60-90 A
100-140 A
140-180 A
200-240 A
-
60-90 A
100-130 A
140-180 A
200-250 A
-
60-100 A
70-130 A
120-170 A
160-200 A
Basic
Cellulosic
Operation