Page 46
4.3.5. Replacing Mertik GV60 Valve (Total Control Model)
Referring to
Figure 76
:-
1.
Remove al the gas connections on the
valve including the pilot feed pipe.
2. Remove the thermocouple connection
from the interrupter block at the rear of
the valve.
3. Pull out the TC cable with the red tab
from the interrupter block.
4. Unscrew the cable with yellow
identifying insulation from the receiver.
5.
Remove the two valve securing screws
and withdraw the valve.
6. Refit the replacement valve in reverse
order ensuring that the valve spacers
are fitted.
Pilot Feed
Pipe
TC Cable
to Receiver
Thermocouple
Connection
Gas
Inlet
Gas
Outlet
Valve
securing
Screw
Valve
securing
Screw
Figure 76
4.3.6. Replacing the Receiver (Total Control Model)
1. Pull out the receiver from under the
heat shield and remove the batteries.
2. Gently pull out the HT lead and the
valve cable from the receiver (see
Figure 77
).
3. Unscrew and remove the SW and TC
connections.
4. Refit in reverse order (the valve cable
plug fits into the receiver in one way
only).
5. Replace the batteries and return the
receiver under the heat shield.
HT
Lead
SW
)
(yellow
TW
( )
red
Valve
Cable
Figure 77
4.3.7. Programming Handset to Receiver (Total Control)
If for some reason the remote handset
requires re-programming to operate the
receiver follow the procedure below:
1.
Press and hold, using a pointed object,
the receiver’s reset button until you
hear two acoustic signals (see
Figure
78
).
2.
After the second longer acoustic signal,
release the reset button and within the
subsequent 20 seconds, press the
(small flame) on the remote handset
until you hear an additional long
acoustic signal confirming the new
code is set.
RESET