Page 37
The fascia
mounting frame
must be flat and level in all
directions when fitted. Failure
to ensure this will result in
poorly fitting fascia (door).
Suitable material may be used
behind the frame fixing points to
level
it.
Gas Spring
Wing Nut
Figure 66
3.9.6. Continuation of Installation - Remote Control Model
1. Unpack the box containing the Receiver
and the Hand Set.
2. Fit four AA (1.5V) batteries into the
receiver unit and the PP3 (9V) battery
into the transmitter (hand set).
3. Feed the cable from the receiver unit
heat shield to the spade terminals on the
control valve, keeping the cable clear of
the underside of the tray. The cable
connectors must be matched to the
appropriately sized spade connector.
4. Position the receiver under the heat
shield as shown in
Figure 67
.
5. Test the operation of the drive motor
using the hand set as per Users
Instructions (
Section 2.1.3 Lighting
Procedure (Remote Control)
on page
6
).
6. Proceed to
Section 3.9.10
to
commission the installation.
Heat
Shield
Receiver
Burner Tray
Tray
Fixing
Screw
Tray
Fixing
Screw
Figure 67