4. 

Press the compressor on/off button on top of the machine. The compressor 
on/off button starts blinking.

5. 

After a maximum of 2.5 minutes, the pressure will be at the maximum pressure 

of 8 bar. The compressor will automatically stop at the set pressure and the 

compressor on/off button turns red.

 

If an external air source is used for the first time, follow the next steps. If an external air 
source is used when the desired quick connector is installed, follow step 5 only:

1. 

Remove the top cover, see Section 4.1.

2. 

Remove the elbow part of the 3-way coupling with an adjustable open-
ended spanner.

3. 

Replace the end plug in the elbow with the desired quick connector suitable 
for the desired quick connector.

4. 

Close the top cover, see Section 4.1.

5. 

Connect the hose from an external air source to the quick coupling. Only use 

an air source with an air filter with a maximum output of 8 bar.

 

3.6 

SHOOT WITH DMX OR PYRO

DANGER

Make sure that the described safety zone is clear of people, 

animals and objects. Not doing so results in death or serious 

injury. 

If DMX is used, follow the next steps:

1. 

Make sure that the prescribed safety zone is free from persons and objects.

2. 

If the safety zone is free, arm the system by turning the key clockwise on the 
MAGICFX

®

 FX-ARM CONTROLLER. The FX LED lights up.

3. 

Activate the enable address. The FX LED begins to flash.

Содержание MFX0408

Страница 1: ... STADIUMSHOT III USER AND INSTALLATION MANUAL CONFETTI STREAMER FX PART01839 rev 01 01 ENGLISH ...

Страница 2: ...ered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use other than that stated in this manual and use other than in accordance with the General Conditions registered at the Chamber of Commerce We further refer to the General Conditions These are available on request free of charge Although considerable care ...

Страница 3: ...afely 14 2 1 General safety rules 14 2 2 Transport 14 2 3 Compressed air 15 2 4 Outdoor use 15 2 5 Rigging 15 2 6 Noise level 15 2 7 Safety symbols 16 2 8 Precautions for operation 16 3 Let s shoot 18 3 1 Install the machine 18 3 2 Connect the machine 24 3 3 Setup multiple machines in a sequence 26 3 4 Fill with confetti and or streamers 27 3 5 Fill with pressurized air 28 3 6 Shoot with DMX or py...

Страница 4: ...is signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation that if not avoided could result in minor or moderate injury NOTICE Indicates information considered important but not hazard related e g messages relating to property damage LANGUAGE This document...

Страница 5: ...air tank The pressure can be set via the machine s display to accommodate different venues When the machine is loaded with MAGICFX CONFETTI or STREAMERS a single push on the physical button on the MAGICFX STADIUMSHOT III will charge the air tank to the set pressure and maintain the pressure at the set value until the shot is fired If for any reason the pressure drops and cannot be compensated the ...

Страница 6: ...R ON OFF BUTTON INDEX PLUNGER TOP COVER OUTPUT PIPE STRAP PLATE REMOVABLE HANDLE WITH AIRFILTER BRAKE COUPLING WITH LOCKING CLAMPS PRESSURE GAUGE DMX INPUT OUTPUT 5 POLE FX WARNING LED POWER INPUT OUTPUT 100 250 VAC FX ARM CONTROLLER INPUT OUTPUT SCREEN BUTTONS VENT VALVE PYRO INPUT 24 VDC Main parts ...

Страница 7: ...densing Electrical Voltage Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consumption Vac 350 W Power Connector Vac Neutrik powerCON TRUE1 in out Controlling Control Options DMX 24 Vdc Control Protocols DMX512 A ANSI E1 11 RDM ANSI E1 20 Control Connectors Neutrik 5 pole male female XLR 4 mm banana socket Safety controlling Control Connectors Neutrik male female etherCON Configuring Config...

Страница 8: ...ger 0 199 No output 200 255 Fire Operation of the DMX addresses When you link multiple machines with DMX we advise you to use the same enable address for all machines CAUTION Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence Using a DMX Terminator improves signal reliability 1 5 DISPLAY PANEL INFORMATION ERROR HISTORY CONFIGURATION DMX RDM SETTINGS Displ...

Страница 9: ... Bootloader CRC Serial Number DDDDD Build Date Software Version Software CRC Uptime DDDD HH MM SS Effect Time DDDD HH MM SS Status Display DMX Start Address 1 512 DMX Enable Address 1 512 DMX Footprint Lock Unlock Controller Reset Errors DMX RDM Settings RDM ON OFF Error History Type Alarm Error Output Distance 0 255 Unique ID HHHHHHHHHHHH Bootloader CRC Serial Number DDDDD Build Date Software Vers...

Страница 10: ...isplay Dimmer On Off Turn display dimmer on or off If turned on the display is dimmed automatically 30 seconds after the last button push Factory Defaults Yes No Restores the appliance factory default settings Type Alarm Error Toggle between the occurred locking error Alarm list and blocking error Error list Locking errors need intervention by user although they are auto reset 3 times before the a...

Страница 11: ...owing RDM parameters are supported by the MAGICFX STADIUMSHOT III Parameter ID Discovery GET SET DISC_UNIQUE_BRANCH X DISC_MUTE X DISC_UN_MUTE X DEVICE_INFO X SUPPORTED_PARAMETERS X SOFTWARE_VERSION_LABEL X DEVICE_MODEL_DESCRIPTION X MANUFACTURER_LABEL X SLOT_DESCRIPTION X SENSOR_DEFINTION X SENSOR_VALUE X DMX_START_ADDRESS X X IDENTIFY_DEVICE X X DEVICE_LABEL X X FACTORY_DEFAULTS X X RESET_DEVICE...

Страница 12: ...III RAIN COVER MFX3220 MAGICFX FX ARM CONTROLLER MFX0313 Schuko to Neutrik powerCON TRUE1 cable 1 5 m Accessories Please contact MAGIC FX for additional possibilities MAIN PARTS MAGICFX FX ARM CONTROLLER POWER INPUT 100 250 VAC ARM CONTROLLER OUTPUT E STOP RESET BUTTON E STOP BUTTON ARM DISARM SAFETY KEY Main parts MAGICFX FX ARM CONTROLLER NOTICE Without the MAGICFX FX ARM CONTROLLER it is not po...

Страница 13: ...REAMERS 20 m x 2 5 cm 9 Polybags 40 m 131 ft 8 bar 116 psi MAGICFX STREAMERS 10 m x 5 cm 15 Polybags 35 m 115 ft 8 bar 116 psi MAGICFX STREAMERS 10 m x 2 5 cm 18 Polybags 35 m 115 ft 8 bar 116 psi MAGICFX STREAMERS 10 m x 1 5 cm 20 Polybags 35 m 115 ft 8 bar 116 psi Projectile types and related loads and output WARNING Always shoot streamers at a minimum of 8 bar pressure to unfold them completely...

Страница 14: ...rations have been made other than by or on behalf of MAGICFX Make sure that children unauthorised people and animals do not obtain access to the MAGICFX STADIUMSHOT III Make sure there are no freestanding objects or objects that can be damaged by the machine within the output distance Make sure that streamers and or confetti cannot come into contact with high voltage lines power pylons as this can...

Страница 15: ... the tank pressure meter to make sure the pressure in the tank is stable and does not exceed 8 bar If necessary depressurize the system by opening the ventilation valve 2 4 OUTDOOR USE The MAGICFX STADIUMSHOT III is designed for outdoor use WARNING The MAGICFX STADIUMSHOT III can be used indoors in large event halls and arenas Please refer to page 17 2 5 RIGGING Please follow the European and nati...

Страница 16: ...us injury or property damage Never leave the machine and the power switch unattended when the machine is ready for use WARNING Do not use the MAGICFX STADIUMSHOT III if alterations have been made other than by or on behalf of MAGICFX DANGER Make sure that streamers and or confetti cannot come into contact with high voltage lines power pylons as this can result in electrocution WARNING Missing or o...

Страница 17: ... zone as shown in the image below clear of all people animals and objects Not doing so results in death or serious injury WARNING Always create a safety zone around the machine with a radius of 5 meters 16 5 feet Make sure unauthorized personnel animals and objects are clear of this area Not doing so can result in death or serious injury 5 m 16 5 ft 4 0 m 1 3 1 f t 45 Confetti Streamers 2 0 m 6 6 ...

Страница 18: ...8 MAGICFX STADIUMSHOT III User and Installation Manual 3 LET S SHOOT 3 1 INSTALL THE MACHINE 1 Bring the cased machine to the desired location 2 Place the machine in its final position and set the brakes ...

Страница 19: ... machine to fixate the machine and prevent it from moving WARNING Always make sure to properly fixate the machine on a stable and suited surface Not doing so can result in death or serious injury NOTICE Do not apply more than 100 kg on the strap plate The flightcase may break down 4 Unlock and remove the flightcase cover ...

Страница 20: ...20 MAGICFX STADIUMSHOT III User and Installation Manual 5 Remove the output pipe 6 Pull the locking clamps downwards to unlock and rotate them upwards ...

Страница 21: ...MAGICFX STADIUMSHOT III User and Installation Manual 21 7 Place the output pipe in the coupling while holding the locking clamps upwards 8 Lock the output pipe in place with the locking clamps ...

Страница 22: ... the clamps outwards to check if the locking pins are properly locked in place If not remove the output pipe and repeat step 5 and 6 WARNING Never use the machine when the clamps are not locked or working properly Not doing so can result in death or serious injury ...

Страница 23: ...t the tank in the desired position Make sure the index plunger is properly in place WARNING Never use the machine when the index plunger is not properly in place or working properly Not doing so can result in serious injury or death 11 Take the necessary safety precautions see Section 2 8 ...

Страница 24: ...ble to the power input The screen will light up 3 Connect an arm cable to the arm in connector on the machine 4 Connect the other end of the arm cable to the MAGICFX FX ARM CONTROLLER 5 Connect the female connector of a 5 pole DMX cable in the DMX input 6 Connect the other end of the DMX cable to the DMX controller 7 Use the display and buttons or a RDM controller to assign DMX addresses see Chapt...

Страница 25: ...TROLLER 5 Connect the power cables to the 24V in pyro connector 6 Connect the other end of the power cables to the external low voltage pyro controller 24 V POWER IN POWER OUT PowerCon TRUE1 female POWER ARM IN ARM OUT ARM EtherCON 24 Vdc 24 Vdc CAUTION It is possible to fire the machine without connecting the PowerCon TRUE1 female connector Note that the compressor will not work without connectin...

Страница 26: ... power output with a power link cable If DMX is used follow the next steps 1 Connect a power link cable between the power output and the power input of the next machine 2 Connect an arm cable between the arm out connector and the arm in connector of the next machine 3 Connect a DMX cable between the DMX output and the DMX input of the next machine 4 Use the buttons or a RDM controller to assign DM...

Страница 27: ...and the gauge pressure is 0 bar Not doing so can result in death or serious injury 1 Place a lifting core in the bottom of the output pipe Make sure the lifting core lies flat and closes off the hole in the output pipe 2 Fill the output pipe with confetti and or streamers Check Chapter 1 for the maximum amount per approved type of input ...

Страница 28: ...tion clear of persons animals or objects Not doing so will result in death or serious injury DANGER Always make sure unauthorized persons animals or objects are not able to get in front of the shooting direction Not doing so will result in death or serious injury If the internal compressor of the MAGICFX STADIUMSHOT III is used follow the next steps 1 Power the machine 2 Close the vent valve 3 Set...

Страница 29: ...y coupling with an adjustable open ended spanner 3 Replace the end plug in the elbow with the desired quick connector suitable for the desired quick connector 4 Close the top cover see Section 4 1 5 Connect the hose from an external air source to the quick coupling Only use an air source with an air filter with a maximum output of 8 bar 3 6 SHOOT WITH DMX OR PYRO DANGER Make sure that the describe...

Страница 30: ...R The FX LED lights up 3 Activate the pyro controller 4 Enjoy the view 5 Deactivate the external low voltage pyro controller 24V 6 Disarm the system by turning the key counterclockwise on the MAGICFX FX ARM CONTROLLER In case of emergency or an unexpected unsafe situation push the emergency button on the MAGICFX FX ARM CONTROLLER The machine is now unable to shoot To reset the MAGICFX FX ARM CONTR...

Страница 31: ...allation Manual 31 3 7 CLEAN UP 1 Turn open the vent valve and make sure the gauge pressure is 0 bar 2 Disconnect the cables 3 Rotate the tank to the vertical 0 position 4 Pull the locking clamps downwards to unlock and rotate them upwards ...

Страница 32: ...32 MAGICFX STADIUMSHOT III User and Installation Manual 5 Remove the output pipe from the coupling 6 Store the output pipe in the flightcase ...

Страница 33: ...MAGICFX STADIUMSHOT III User and Installation Manual 33 7 Remove the lashing ratchet 8 Place and lock the flightcase cover 9 Release the brakes ...

Страница 34: ... Contact MAGIC FX if the machine is not functioning correctly DANGER Do not replace parts yourself other than specified in this chapter always consult MAGIC FX DANGER Never clean the machine or do maintenance to the machine with the tank pressurized Always make sure the vent valve is open 4 1 CLEANING 1 Remove the top cover by removing the six screws of the top cover with a TORX20 screwdriver 2 Cl...

Страница 35: ...Replace the air in filter element periodically The replacement frequency depends on operating frequency and operating environment For frequent use in dusty environments MAGIC FX recommends to replace the air infilter element once a month 1 Remove the handle of the machine by removing the ten inbus 3 screws of the handle 2 Remove the air in filter housing from the machine by rotating clockwise ...

Страница 36: ...n Manual 3 Open the plastic housing of the air in filter 4 Replace the air in filter 5 Close the plastic housing of the air in filter 6 Screw the air in filter housing back into the machine 7 Attach the handle of the machine with the inbus 3 screws ...

Страница 37: ... the vent valve Press the compressor on off button to pressurize again Wait until the STADIUMSHOT III has built up the set pressure Fire again If the problem is not solved contact MAGIC FX 121 Orientation of device out of safe bounds The machine is tilted more than allowed Turn the machine to a level position 123 Pressure too high Open the vent valve Close the vent valve when the warning has disap...

Страница 38: ...f charge Alternatively in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for fu...

Страница 39: ...RoHS 2011 65 EU Restriction of the use of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment PED 2014 68 EU Pressure Equipment The following harmonized standards were applied NEN EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction NEN EN IEC 60204 2018 Safety of machinery Electrical equipment of machines Part 1 Gene...

Страница 40: ...WWW MAGICFX EU ...

Отзывы: