24 MAGICFX
®
STADIUMSHOT III
—
User and Installation Manual
3.2
CONNECT THE MACHINE
1
Make sure that the power output on your controller or power switch is disabled.
2
If DMX is used, follow the next steps:
1.
Connect a power cable with a PowerCon TRUE1 female connector to a
100-250 Vac (50-60 Hz) power source.
2.
Connect the other end of the power cable to the power input. The
screen will light up.
3.
Connect an arm cable to the arm in connector on the machine.
4.
Connect the other end of the arm cable to the MAGICFX
®
FX-ARM
CONTROLLER.
5.
Connect the female connector of a 5-pole DMX cable in the DMX input.
6.
Connect the other end of the DMX cable to the DMX controller.
7.
Use the display and buttons or a RDM controller to assign DMX
addresses, see Chapter 1.
POWER IN
POWER OUT
PowerCon TRUE1 female
POWER
DMX
DMX IN
DMX OUT
5-pole female
DMX IN
DMX OUT
DMX IN
DMX OUT
ARM IN
ARM OUT
ARM
EtherCON