26 MAGICFX
®
STADIUMSHOT III
—
User and Installation Manual
3.3
SETUP MULTIPLE MACHINES IN A SEQUENCE
CAUTION
Do not connect more units to a single electrical circuit than the
installed fuse is able to handle. (Calculate the summed load with
the electrical data from Chapter 1)
NOTICE
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal and reliabillity.
1
Optionally connect another machine to the power output with a power link
cable.
If DMX is used, follow the next steps:
1.
Connect a power link cable between the power output and the power
input of the next machine.
2.
Connect an arm cable between the arm out connector and the arm in
connector of the next machine.
3.
Connect a DMX cable between the DMX output and the DMX input of
the next machine.
4.
Use the buttons or a RDM controller to assign DMX addresses, see
Chapter 1.
5.
Repeat step 1 to 4 for each subsequent machine.
PowerCon TRUE1 female
PowerCon TRUE1 male
POWER
POWER IN POWER OUT
POWER IN POWER OUT
5-pole female
5-pole male
DMX
DMX IN
DMX OUT
DMX IN
DMX OUT
ARM IN
ARM OUT
ARM
EtherCON
EtherCON
ARM IN
ARM OUT