If pyro is used, follow the next steps:
1.
Connect a power cable with a PowerCon TRUE1 female connector to a
100-250 Vac (50-60 Hz) power source.
2.
Connect the other end of the power cable to the power input. The
screen will light up.
3.
Connect an arm cable to the arm in connector on the machine.
4.
Connect the other end of the arm cable to the MAGICFX
®
FX-ARM
CONTROLLER.
5.
Connect the power cables to the 24V in pyro connector.
6.
Connect the other end of the power cables to the external low voltage
pyro controller (24 V).
POWER IN
POWER OUT
PowerCon TRUE1 female
POWER
ARM IN
ARM OUT
ARM
EtherCON
24 Vdc +
24 Vdc -
CAUTION
It is possible to fire the machine without connecting the
PowerCon TRUE1 female connector. Note that the compressor will
not work without connecting power and the warning LED will not
light up when enabling the MAGICFX
®
FX-ARM CONTROLLER.
Pressure safety checks will not work and it is possible to shoot
confetti andstreamers at an unsafe pressure. See Section 1.8.