EN
EN
Programming menu No. 1
When the door is open and ignition is on keep buttons
I
and
II
pressed simultaneously for 2
sec.
Options
No.
Function
Button I
Button II
Button III
Button IV
1-01
TURBO mode
Off
2 min
1 min
-
1-02
Regular starting
Off On
- -
1-03
Engine running time
10 min
25 min
3 min
5 min
1-04
Emergency code RPS
Off On
- -
1-05
Reservation mode set-up
By closing the
door
By closing the
door and pressing
button
l
By closing the
door+turning
alarm on
-
1-06
Flashing when the doors
are open
Off
On
-
-
1-07
Heating time
3 sec
5 sec
8 sec
12 sec
1-08
Flashing when the hood
is open
Off On
- -
1-09
Engine sensing
Alternator Revs
-
-
1-10
PIN code
Off On
- -
1-11
Start kill/IG kill
IG kill
Start kill
-
-
1-12
Dome light delay
Off
5 sec
15 sec
50 sec
1-13
Ultrasonic input off
during remote start
Off On
1-14
CAN mode
Read Read/Write
Read/Write/
Wiindow roll up
Functions description:
1-01
When on, the engine remains running after the hand brake has been pulled, ignition is off
and the doors are closed. While the engine running, lights are flashing, remote is displaying the
remaining time of engine running. You can set 1 or 2 minutes of engine running.
1-02
When on, the alarm will try to start the car up at the pre-set time. The function requires
activating the function on the remote, setting the time of the start up and setting the reservation
mode.
1-03
Setting the engine running time when remotely started.
1-04
When on, you can enter a 4-digit emergency code to cancel the alarm and open the car.
1-05
By choosing this option, you can set up the conditions for a reservation mode set-up. For
reservation mode setting to carried out, transmission must be in a neutral position, emergency
brake pulled up with the engine running. By turning ignition off the engine remains running and
reservation mode will be set after choosing the option in programming menu 1-05. When choosing
option No.3, the alarm will arm.
1-06
When on, alarm will warn of the door opened by flashing the lights.
1-07
You can set the time for heating in diesel cars. It is also possible to set the time during
which the alarm will keep the ignition and accessories on when remotely started.
1-08
When on, alarm will warn that the hood is open by flashing the lights.
1-09
you can choose the type of engine sensing.
- alternator – input 12V required immediately after the engine is started and less than 5V when
turned off.
- revs – you can use the sensor’s impulses based on the revs.
1-10
It allows you to enter the valet mode in two ways:
- simple access – by turning ignition on/off 3 times in row
- secure access – by turning ignition on/off 3 times in row and entering a 2-digit PIN code by the
button on the back side of RPS.
1-11
In case of using the
IG kill
function, the blocking output is – active (on -250mA) when
armed, - inactive during a remote starting and disarmed; in case of using the PANIC function when
disarmed, the output will be activated after 30 sec. In case of using the S
tart kill
function, blocking
output is – active when armed and remotely started, - inactive when disarmed; in case of using the
PANIC function when disarmed, the output will be activated immediately.
1-12
It is possible to set up a delayed reaction to opened door contacts when turning on the
alarm. The function is supposed to be used with indirect closed doors scanning (from the roof light,
etc.)
11