Installation Instructions
INSTALLATION DRAWINGS
-2-
“A” = 30” (76.2 CM) - 31” (78.7 CM) FOR CANADA
“B” = 7” (17.8 CM) - 7 1/2” (19.1 CM) FOR CANADA
FIGURE 2
“B”
“A”
CABINET OPENINGS,
UPPER & LOWER
PROVIDE FOR 400/230 VOLT
THREE PHASE OUTLET PER
APPLICABLE CORD IN THIS
AREA.
16”
40.6 CM
36” (91.5 CM)
COUNTER TOP HEIGHT
5 3/4”
(14.6 CM)
24” (61 CM)
CABINET DEPTH
25” (63.5 CM)
NORMAL COUNTER
TOP DEPTH
“A” = 30 inches (76.2 cm) minimum clearance between
the top of the cooking surface and the bottom of an
unprotected wood or metal cabinet, or “A” = 24 inches
(61 cm) minimum when bottom of wood or metal
cabinet is protected by not less than 1/4-inch (6.4 mm)
thick flame-retardant millboard covered with not less
than No. 28 MSG sheet steel, 0.015-inch (0.381 mm)
thick stainless steel, 0.024-inch (0.610 mm) thick
aluminum, or 0.020-inch (0.508 mm) thick copper.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches (13 cm) beyond the bottom of the
cabinets.
FIGURE I
1, 2, 3 - COMBUSTIBLE BUILDING WALLS.
4 - COMBUSTIBLE WALL CABINET.
A freestanding range may be installed adjacent to (0"
from) combustible walls 1, 2 & 3.
NOTE:
Figure may not be representative of actual unit.
FIGURE 1
IMPORTANT
PLEASE KEEP FOR THE USE OF THE
LOCAL ELECTRICAL INSPECTOR.