Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
© 2006 Maytag Services
16026839
13
Illustration Component
Test
Procedure
Results
NSC Controlled
Oven Temperature
Adjustment
Press
Bake
pad.
Enter
550
on the digit-pad.
Immediately press and hold
Bake
pad
for 3 to 5 seconds.
Oven can be adjusted from -35 to +35
degrees in 5-degree increments by
pressing
Up
or
Down Arrow
pads. To
avoid over adjusting the oven, move
temperature 5 degrees each time.
Wait 4 seconds for the data entry timer
to expire to accept the change.
Temperature adjustment will be
retained even through a power failure
.
While increasing or decreasing oven
temperature, this does not affect self-
cleaning temperature.
NSC Controlled
Keypad Lockout
Press and hold
Cancel
and
Timer
pads for 3 to 5 seconds. Press
Up
or
Down Arrow
pads to change.
This mode disables keypad input to deter
against accidental keypad entries.
NSC Controlled
Temperature Display
Press and hold
Cancel
and
Bake
pads for 3 to 5 seconds. Press
Up
or
Down Arrow
pads to change.
This mode enables the user to indicate
°F or °C on the display.
NSC Controlled
Sabbath Mode
Hold
Clock
pad for 3 to 5 seconds to
activate Sabbath mode.
Hold
Clock
pad for 3 to 5 seconds to
disable Sabbath mode.
Desired bake function must be
initiated before entering Sabbath
mode.
"SAb" flashes for 5 seconds, then
remains on until timed-out or cancelled.
The status "SAb" is NOT fault code 5A6.
All pad inputs are disabled except for
CANCEL
and
CLOCK
pads.
This mode disables the normal 12 hour
shutoff to allow operation of the bake
mode for a maximum of 72 hours.
The oven light is not disabled.
NSC Controlled
Twelve Hour Off
Control will automatically cancel any
cooking operation and remove all
relay drives 12 hours after the last pad
touch.
See Sabbath mode to disable.
NSC Controlled
Diagnostic Code
Display
Press and hold
Up Arrow
pad for 3 to
5 seconds when applying power to the
unit.
Cycle through the codes using the
Up
or
Down Arrow
pads.
The last 5 diagnostic codes will be stored
in the non-volatile memory.
See
"Description of Error Codes"
for
explanation.
NSC Controlled
One-Watt Standby
Mode
Press and hold
Cancel
and
Down
Arrow
pads for 3 to 5 seconds.
After 15 idle minutes, the control
automatically enters this mode. The LED
display remains active.
Содержание CER3725AGW