Installation
MultiView™ II DVI-Rx-1K
Installation and User Guide
11
5.7
Configuration Settings
There are a number of configurable operating parameters, and the factory-default settings should work for most
applications. However, some applications might require slight configuration changes.
This section describes how to configure the following settings:
Config-mode, LEDs 1-3:
4
th
pair settings
Config-mode, LED 4:
4
th
pair termination settings
All settings are available from the front-panel buttons/LEDs. The enclosure does not need to be opened
unless
the SAP option module is being installed or removed, or settings specific to the option module need to be
changed.
5.7.1 Configuration Mode
For changing configuration settings, the receiver must be in configuration mode (CFG indicator is on). Once in
configuration mode, any changes are effective immediately and are saved in non-volatile memory.
To enter configuration mode:
Press and hold the
CFG button
until the
CFG
indicator
is
ON
.
o
Once in this mode, the LED indicators 1-8 will display the current settings as described in the
tables below.
To exit configuration-mode:
Leave the buttons untouched for 10 seconds. The
CFG indicator
will turn off (normal-mode).
To quickly reset all user-configurable options back to factory-default settings:
1. Disconnect the DC power cable (or AC power).
2. Press and hold the
CFG
button.
3. Connect the DC power cable (or AC power). All LEDs blink 3 times, indicating all settings are now changed
back to factory-defaults.
4. Release the
CFG
button.