background image

 

Installation 

 

MultiView™ II DVI-Rx-1K 

Installation and User Guide 

Chapter 5 

Installation 

 
This section describes the following installation topics: 
 

 

Data mode configuration 

 

Prerequisites to installation 

 

Installation procedure 

 

Post-installation adjustments 

 

Post-installation configuration settings 

 

 

This equipment is not intended for, nor does it support, distribution through an Ethernet network.  
Do not connect these devices to any sort of networking or telecommunications equipment!   

 

 

Do not connect DC power until instructed to do so.

 

 

5.1 

Option-Module Configuration 

 
If you are installing a MVII-DVI-Rx-1K-

SAP

 version receiver (this is equipped with the SAP hardware option 

module), then the following information will be important to review BEFORE installing the receiver: 
 
The 

MVII-DVI-Rx-1K-SAP

 version offers pollable RS232 duplex serial in addition to true stereo audio. The 

serial interface is a 3-wire (TX, RX, GND) interface. The factory-default serial baud rate is 9600 baud, but this is 
a user-

configurable option using “SAP-II” serial commands. Simplex modes are supported without jumper or 

other changes by simply using the TX signal only. The serial-polling capability allows interaction with specific 
receivers. This will require that each receiver have a unique SAP-address setting. Please refer to Appendix-B 
for (SAP) module configuration information, and Appendix-C for SAP-address settings. 

5.2 

Prerequisites 

 
Depending on the specific installation requirements, some common tools (screwdrivers, nut-drivers) and related 
hardware (mounting screws) might be required. These are not provided with Magenta products. 
 
The following items might be necessary, which are available from Magenta Research: 
 

 

Audio cable: Phoenix 4-pin to RCA. 

 

Video cable: DVI (or HDMI with an appropriate DVI/HDMI adapter) 

 

Serial cable: Phoenix 4-pin to DB9, or one of several DB9-M/F, M/M or F/F extension cables. 

 

Note:

 You will need appropriate twisted-pair cable as previously described, to connect the MVII-DVI-Rx-1K to 

other 

MultiView™ II devices. tvONE does not supply this cable.

 

5.3 

Installation Procedure 

 

Ensure that all connectors are clean and free of contaminants prior to making the 
connections. Appropriate connector locking hardware (screws/latches) should be used to 
prevent cables from disconnecting or causing intermittent operation.  

All units must be the same type for 4

th

-pair supported features to function correctly. For 

example, a “MVII-DVI-Tx-A” must be paired with a MVII-DVI-Rx-1K-A, as both must be 
identical to work properly. Similarly, an 

“MVII-DVI-Tx-SAP” can only be used with an MVII-

DVI- Rx-1K-SAP

”. Video modes may function normally, but 4th pair options will not. 

 

Содержание MultiView II DVI-Rx-1K

Страница 1: ...ultiView II DVI Rx 1K Receiver Installation and User Guide Version 1 00 2791 Circleport Drive Erlanger KY 41018 USA Americas 859 282 7303 EMEA 44 0 1843 873322 Email tech usa tvone com www tvone com T...

Страница 2: ...tware or documentation including their quality performance merchantability or fitness for a particular purpose As a result this software or documentation are licensed as is and you the licensee are as...

Страница 3: ...ique de la classe A est conforme a la norme NMB 003 du Canada EUROPEAN UNION DECLARATION OF CONFORMITY Warning This is a Class A product In a domestic environment this product may cause radio interfer...

Страница 4: ...nt or from the power source receptacle wall plug Power cord protection Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servici...

Страница 5: ...es 6 5 3 Installation Procedure 6 5 4 Adjustments 9 5 5 Cable Distance EQ Compensation Settings 9 5 6 Skew Compensation Settings 10 5 7 Configuration Settings 11 5 7 1 Configuration Mode 11 5 7 2 4th...

Страница 6: ...og audio outputs Capable of driving a 10K ohm load unbalanced S PDIF mode For S PDIF digital audio 75 Ohm typical impedance Note The DVI Tx transmitter can also de embed 2CH PCM digital audio which ca...

Страница 7: ...ibility issues The following table shows the factory configured versions of the MVII DVI Rx 1K Table 2 Available MVII DVI Rx 1K Versions Version Description MVII DVI Rx 1K A Base model factory configu...

Страница 8: ...total per color channel to cancel the effects of skew in Category cables This feature allows you to use a variety of UTP cables both normal and minimized skew types to lengths up to 1000ft 305m The MV...

Страница 9: ...Rear Panel Interfaces The rear panel of the MVII DVI Rx 1K has the following ports DB9 serial port optional on SAP model only Video output to display UTP link output port Figure 2 MVII DVI Rx 1K Rear...

Страница 10: ...nd is incompatible with our products Ensure that any low skew cable is non proprietary before purchase and installation CAT6 cable due to the manufacture method can exhibit much greater skew than stan...

Страница 11: ...ll require that each receiver have a unique SAP address setting Please refer to Appendix B for SAP module configuration information and Appendix C for SAP address settings 5 2 Prerequisites Depending...

Страница 12: ...nnector labeled DVI IN 2 If desired attach a local monitor to the DVI D connector labeled LOCAL OUT if available 3 Make your audio or serial connections via the AUX I O Phoenix connector or DB9 connec...

Страница 13: ...6 IMPORTANT The MVII DVI Rx 1K will auto adjust the EQ and Skew settings This is the factory default behavior However in some applications it will be necessary to manually fine tune these adjustments...

Страница 14: ...results use the Magenta EQ Skew test pattern image if possible A test pattern image and video instructions is available at http www magenta research com test The following figure shows the test image...

Страница 15: ...The following figure shows the test image you can use to make the SKEW adjustment Figure 6 Image Adjustment Utility Skew To adjust skew 1 From normal mode press and hold the SKEW SEL button until the...

Страница 16: ...nged 5 7 1 Configuration Mode For changing configuration settings the receiver must be in configuration mode CFG indicator is on Once in configuration mode any changes are effective immediately and ar...

Страница 17: ...on LED indicators 1 3 should be illuminated either DIM or ON all others indicators 4 8 should be off Press the UP or DOWN buttons to step through the available 4th pair settings as shown below To leav...

Страница 18: ...s is the factory default Set to OFF only for mid span receivers in a daisy chain configuration Perform the following procedure while the receiver is in the normal operating state CFG indicator is off...

Страница 19: ...sure receiver EQ and SKEW adjustments are set correctly Change EQ settings slowly while making manual adjustments Check all cable connections There may be a video skew delay issue your cable may have...

Страница 20: ...table below provides the pin out for all 24 pins which are used in the DVI Rx 1K unit Pin Signal Name Pin Signal Name Pin Signal Name 1 TMDS Data 2 9 TMDS Data 1 17 TMDS Data 0 2 TMDS Data 2 10 TMDS...

Страница 21: ...O Connector Pinout Table 5 Auxiliary I O 4 pin Phoenix Pin Usage PIN A Audio SAP Audio S Simplex Serial SPDIF Audio 1 SIG1 Left Channel Left Channel Tx Signal 2 GND Ground Ground ground Signal 3 SIG2...

Страница 22: ...ial connector configured to look like a standard 9 pin DTE serial port Therefore in most applications a straight through serial cable or adapter plug DB9 Female to Male is used to connect an external...

Страница 23: ...e 9 T568B Category Cable Wiring Standard Table 7 T568B wiring for RJ 45 plug PIN COLOR PAIR 1 White Orange Stripe 2 2 Orange Solid 2 3 White Green Stripe 3 4 Blue Solid 1 5 White Blue Stripe 1 6 Green...

Страница 24: ...accepted center pin diameter Length 11mm overall length of insertable plug end Inner contact pin socket 5VDC Outer contact sleeve Ground It is highly recommended that the inner contact center pin cont...

Страница 25: ...4 60Hz 24 1280x720 progressive scan 59 95 or 60 Hz 24 bit color 720p 50Hz 24 1280x720 progressive scan 50 Hz 24 bit color 1080p 60Hz 24 1920x1080 progressive scan 60 Hz 24 bit color 1080p 59 94Hz 24 1...

Страница 26: ...r s address switches you will need to open the receiver enclosure and set the DIP switches directly on the SAP module The DIP switch has 8 switches one for each address bit position Use the SAP addres...

Страница 27: ...F 1 2 3 4 6 8 OFF 1 2 3 4 8 OFF 1 5 ON 1 5 6 ON 1 5 7 ON 1 5 6 7 ON 2 3 4 6 7 8 OFF 2 3 4 7 8 OFF 2 3 4 6 8 OFF 2 3 4 8 OFF 2 5 ON 2 5 6 ON 2 5 7 ON 2 5 6 7 ON 1 3 4 6 7 8 OFF 1 3 4 7 8 OFF 1 3 4 6 8...

Страница 28: ...ON 1 5 6 7 8 ON 2 3 4 6 7 OFF 2 3 4 7 OFF 2 3 4 6 OFF 2 3 4 OFF 2 5 8 ON 2 5 6 8 ON 2 5 7 8 ON 2 5 6 7 8 ON 1 3 4 6 7 OFF 1 3 4 7 OFF 1 3 4 6 OFF 1 3 4 OFF 1 2 5 8 ON 1 2 5 6 8 ON 1 2 5 7 8 ON 1 2 5...

Страница 29: ...Mounting Kit Description 2211054 01 Rigid mount bracket This mounts a single device to a surface wall desk etc Comes with 4 self tapping screws 8310203 02 1U Rack mount Plate for standard 19 rack Moun...

Страница 30: ...thin a rack assembly cable bundles and other equipment in the same rack can impede proper cooling In some rack mount applications you may even need to leave a 1U gap using a blank filler plate between...

Страница 31: ...I O 16 DC power 19 DVI Port 15 Link RJ45 18 serial 17 Default settings 11 Front panel interfaces 3 Installation 6 prerequisites 6 procedure 6 SAP Module Configuration 6 Mounting kits 24 Option module...

Страница 32: ...MultiView II DVI Rx 1K Installation and User Guide 27 NOTES...

Страница 33: ...MultiView II DVI Rx 1K Installation and User Guide 28 2791 Circleport Drive Erlanger KY 41018 USA Americas 859 282 7303 EMEA 44 0 1843 873322 Email tech usa tvone com www tvone com...

Отзывы: