Zone Programming
Section
Description
Zone Definition
Partition Assignment
Zone Options
[001]
=
Zone
1:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[002]
=
Zone
2:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[003]
=
Zone
3:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[004]
=
Zone
4:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[005]
=
Zone
5:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[006]
=
Zone
6:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[007]
=
Zone
7:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[008]
=
Zone
8:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[009]
=
Zone
9:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[010]
=
Zone
10:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[011]
=
Zone
11:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[012]
=
Zone
12:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[013]
=
Zone
13:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[014]
=
Zone
14:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[015]
=
Zone
15:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[016]
=
Zone
16:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[017]
=
Zone
17:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[018]
=
Zone
18:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[019]
=
Zone
19:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[020]
=
Zone
20:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[021]
=
Zone
21:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[022]
= Zone 22:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[023]
=
Zone
23:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[024]
=
Zone
24:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[025]
=
Zone
25:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[026]
=
Zone
26:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[027]
=
Zone
27:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[028]
=
Zone
28:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[029]
=
Zone
29:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[030]
=
Zone
30:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[031]
=
Zone
31:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
[032]
=
Zone
32:
_______________
_____/_____
_____________
1 2 3 4 5 6 7 8
Zone Definitions
00 = Zone disabled
01
= Entry Delay 1
02
= Entry Delay 2
03
= Entry Delay 1/Stay/Sleep
04
= Entry Delay 2/Stay/Sleep
05
= Follow
06
= Follow /Stay
07
= Follow/Stay/Sleep
08
= Instant
09
= Instant/Stay
10
= Instant/Stay/Sleep
11
= Instant Fire
12
= Delayed Fire
13
= Instant Fire Silent
14
= Delayed Fire Silent
15
= 24Hr. Buzzer
16
= 24Hr. Burglary
17
= 24Hr. Hold-up
18
= 24Hr. Gas
19
= 24Hr. Heat
20
= 24Hr. Water
21
= 24Hr. Freeze
Zone Options
[1] = Auto-zone Shutdown
[2] = Bypassable Zone
[3]
=
RF Supervision
[4] [5]
OFF OFF Audible Alarm
OFF ON Pulsed Alarm
ON OFF Silent Alarm
ON ON Report Only
[6] = Intellizone
[7] = Delay alarm transmission
[8] = Force Zone
Partition Assignment
[0]- No partition
[1]- Partition 1
[2]- Partition 2
[3]- Both partitions
For UL installation, fire zone cannot be
bypassable. Turn off option 2 of the zone option.