Magellan
35
Appendix 2: Automatic Report Code List
System Event
Default Contact ID Report Code
when using sections [790] to [795]
Default SIA Report Code
when using sections [790] to [795]
Arming with User Code (##)
3 4A1 - Close by user
CL - Closing report
Auto arming
3 4A3 - Automatic close
CA - Automatic closing
Late to close
3 452 - Late to close
OT - Late to close
No movement
3 452 - Late to close
NA - No activity
Partial arming
1 574 - Group bypass
CG - Close area
Quick arming
3 408 - Quick arm
CL - Closing report
Arm with PC software
3 4A7 - Remote arm/disarm
CL - Closing report
Disarm with User Code (##)
1 4A1 - Open by user
OP - Opening report
Disarm after alarm* with User Code (##)
1 4A1 - Open by user
OP - Opening report
Cancel alarm** with User Code (##)
1 4A6 - Open by user
OR - Disarm from alarm
Auto-arming cancellation
1 4A5 - Deferred open/close
CE - Closing extend
Disarm with PC software
1 4A7 - Remote arm/disarm
OP - Opening report
Disarm after an alarm with PC software
1 4A7 - Remote arm/disarm
OR - Disarm from alarm
Cancel alarm with PC software
1 4A6 - Open by user
OR - Disarm from alarm
Cancel paramedic alarm
1 4A6 - Open by user
OR - Disarm from alarm
Zone bypassed (##)
1 57A - Zone bypass
UB - Untyped zone bypass
Zone alarm (##)
1 13A - Burglary alarm
BA - Burglary alarm
Fire alarm (##)
1 11A - Fire alarm
FA - Fire alarm
Zone alarm restore (##)
3 13A - Burglary alarm restore
BH - Burglary alarm restore
Fire alarm restore (##)
3 11A - Fire alarm restore
FH - Fire alarm restore
Panic 1 - emergency
1 12A - Panic alarm
PA - Panic alarm
Panic 2 - medical
1 1AA - Medical alarm
MA - Medical alarm
Panic 3 - fire
1 115 - Pull station
FA - Fire alarm
Recent closing
3 4AA - Open/Close
CR - Recent closing
Global zone shutdown
1 574 - Group bypass
CG - Close area
Duress alarm
1 121 - Duress
HA - Hold-up alarm
Keypad lockout
1 421 - Access denied
JA - User code tamper
Zone shutdown (##)
1 57A - Zone bypass
UB - Untyped zone bypass
Zone tampered (##)
1 144 - Sensor tamper
TA - Tamper alarm
Zone tamper restore (##)
3 144 - Sensor tamper restore
TR - Tamper restoral
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.
AC failure
1 3A1 - AC loss
AT - AC trouble
Battery failure
1 3A9 - Battery test failure
YT - System battery trouble
Auxiliary supply trouble
1 3AA - System trouble
YP - Power supply trouble
Bell output current limit
1 321 - Bell 1
YA - Bell fault
Bell absent
1 321 - Bell 1
YA - Bell fault
Clock lost
1 626 - Time/date inaccurate
JT - Time changed
Fire loop trouble
1 373 - Fire trouble
FT - Fire trouble
RF interference
1 344 - RF receiver jam detection
XQ - RF Interference
TLM trouble restore
3 351 - Telco 1 fault restore
LR - Phone line restoral
AC failure restore
3 3A1 - AC loss restore
AR - AC restoral
Battery failure restore
3 3A9 - Battery test restore
YR - System battery restoral