D.
Diagnostics
Screen 11.2-14: MWAN Interface and Service Diagnostics
Parameters
Description
MWAN Interface
Diagnostics
Select the interface to run the diagnostic test on.
Click one of the following diagnostic test that must
be performed on the selected Interface:
Ping Default Gateway –
Ping the default
gateway configured for the Network Interface.
The gateway is reachable if a ping response is
received else there is a problem in the local
network.
Pink Tracking IP -
Ping the tracking IP
Address configured in MWAN for the Network
Interface. The tracking IP Address is reachable if
a ping response is received else there is a
conflict in the network configuration on the
default gateway.
Check IP Rules
– Click to verify the Interface.
Check Routing Table
– Click to verify the
routes present in the routing table of E200
Router.
Hotplug ifup –
Click to turn-up the Interface
using the hotplug script.
Note
If the interface is already up, the
hotplug
script
will
restart
the
Interface.
Hotplug ifdown –
Click to turn down the