13
IT
EN
FR
ES
XV(F)-1-3-6
Madas Technical Manual
- 1|1.5cX - REV. 1 of 10
th
Sep 2020
1.0 - GENERAL INFORMATION
This manual shows you how to safely install, operate and use the device.
The instructions for use
ALWAYS
need to be available in the facility where the device is installed.
ATTENTION: installation/wiring/maintenance need to be carried out by qualified staff (as explained
in section 1.3) using appropriate personal protective equipment (PPE).
For any information pertaining to installation/wiring/maintenance or in any case problems that cannot be resolved with the use
of the instructions, it is possible to contact the manufacturer from the address and phone numbers provided on the last page.
1.1 - DESCRIPTION
Normally closed automatic fast opening solenoid valves for gas. They open the flow of gas when the coil is electrically powered
and close them when power is disconnected. They can be controlled by pressure switches, thermostats, etc.
They can be equipped with CPI switches to control the valve’s obturator position (closed) remotely. The CPI can also be
installed at a later time
ONLY IF
the device is set-up properly (cap under the valve body). Further information regarding the
CPI switch is available in 6.0.
Reference standards: EN 161 - EN 13611 - EN 60079-0-7-14-15-31.
1.2 - KEY OF SYMBOLS
1.3 - QUALIFIED STAFF
These are people who:
• Are familiar with product installation, assembly, start-up and maintenance;
• Know the regulations in force in the region or country pertaining to installation and safety;
• Are trained in first aid.
1.4 - USING NON-ORIGINAL SPARE PARTS
• To perform maintenance or change parts (ex. coil, etc.)
ONLY
manufacturer-recommended parts can be used. Using
different parts not only voids the product warranty, it could compromise correct device operation.
• The manufacturer is not liable for malfunctions caused by unauthorised tampering or use of non-original parts.
1.5 - IMPROPER USE
• The product must only be used for the purpose it was built for.
• It is not allowed to use different fluids than those expressly stated.
• The technical data set forth on the rating plate must not be exceeded whatsoever. The end user or installer is in charge of
implementing proper systems to protect the device, which prevent exceeding the maximum pressure indicated on the rating
plate.
• The manufacturer is not responsible for any damage caused by improper use of the device.
ATTENTION:
Attention
is drawn to the technical
details intended for
qualified staff.
DANGER:
In the event of
inobservance, this may cause damage
to tangible goods, to people and/or
pets.
DANGER:
In the event
of inobservance, this may
cause damage to tangible
goods.