background image

 

Introduction

 

MacroAir AirLynk 

 

© 2019 MacroAir Technologies     Toll Free: 866 668-3247     Fax: 909 890-2313     www.macroairfans.com   

Rev Date: 071519 

Caution and Safety  

 

ATTENTION:

 

Safety.

 

READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN. Ensure that 

all safety practices and instructions are followed during the installation, operation and servicing 
of the fan. Failure to apply these safety practices could result in death or serious injury. If you do 
not understand the instructions, please call our Technical Department for guidance. 

 

ATTENTION:

 

Qualified  Technicians.

  All  fan  controls  and  incoming  power  should  only  be 

installed by qualified technicians familiar with the requirements of the  National Electrical Code 
(NEC)  and  local  codes.  Refer  to  appropriate  portions  of  this  manual  for  other  important 

requirements. Failure to follow these guidelines will void the manufacturer’s warranty.

 

 

ATTENTION:

 

Code Compliance.

 Installation is to be in accordance with the NEC, ANDSI/NFPA 

70-1999 and local codes. 

 

Hazard of Electrical Shock, Explosion or Arc Flash: 

 

ATTENTION:

 

Read.

 Read and understand this manual before installing or operating a fan unit. 

Installation, adjustment, repair, and maintenance must be performed by qualified personnel. 

 

ATTENTION:

 

Code Compliance.

 The user is responsible for compliance with all international 

and National Electrical Code requirements with respect to grounding of all equipment. 

 

WARNING:

 

Do  Not  Touch.

  Many  of  the  parts  of  this  unit  operate  at  line  voltage.  DO  NOT 

TOUCH. 

 

WARNING:

 

Covers.

 

Install all covers before applying power or starting and stopping the unit. 

 

Installation and Service 

 

WARNING:

 

Damage.

 Do not operate or install any fans or fan accessories that appear to be 

damaged. 

 

WARNING:

 

Death  and  Injury.

  Failure  to  follow  this  instruction  can  result  in  death,  serious 

injury, or equipment damage. 

 

WARNING:

 

Disconnect Power.

 

If the fan does not operate properly using the procedures in 

this  manual.  BE  CERTAIN  TO  REMOVE  ALL  POWER  TO  THE  UNIT  and  contact  our  technical 
department for further assistance. 

 

CAUTION:

 

Moving Parts.

 Keep all body parts clear of moving parts at all times. 

 

ATTENTION:

 

Qualified Technicians.

 All electrical troubleshooting and repair must be done by 

a qualified technician and meet all applicable codes. 

 

REFER TO FAN INSTALLATION MANUAL(S) FOR FURTHER MAINTENANCE INFORMATION. 

Содержание AirLynk BACnet

Страница 1: ...Operation Manual MacroAir AirLynk BACnet...

Страница 2: ......

Страница 3: ...k Wiring Instructions 5 Repeater Install for 370 Fans 6 Network Wiring Requirements Daisy Chain 7 Improper Wiring Configuration Proper Wiring Configuration 8 Excess Cable at Connection Point 9 Wiring...

Страница 4: ...Read and understand this manual before installing or operating a fan unit Installation adjustment repair and maintenance must be performed by qualified personnel ATTENTION Code Compliance The user is...

Страница 5: ...r customizes fans to operate in a network by Addressing the fans and For 370 Fans Supplying an additional length of CAT5 Note For 370 Fans Repeaters Isolators must be added every 5 fans for stability...

Страница 6: ...Introduction MacroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 4 AirLynk Enclosure Dimensions Components...

Страница 7: ...roAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Network Wiring Instructions Refer to the appropriate fan installation manual for specific networking ins...

Страница 8: ...croairfans com Rev Date 071519 Repeater Install for 370 Fans Repeater Isolator The Repeater Isolator boosts the signal along the network preventing signal loss and minimizes noise on the line Repeater...

Страница 9: ...tromagnetic interference For 370 Fans Ground the shielding and drain wire at only one point of the cable run Add Repeaters Isolators 1 5fans Daisy Chain Networked MacroAir fans must be connected in on...

Страница 10: ...acroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Improper Wiring Configuration End of Line x3 End of Line x8 Proper Wiring Config...

Страница 11: ...ypical industrial commercial environment extra cable should not be coiled up as the coil itself will create noise interference in the communication signal There should be no more than two feet of exce...

Страница 12: ...chnologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Wiring CAT5E Pin Out CAT5E B to MacroAir Equipment Pin Out Note For Fire Alarm assignment on existing networks u...

Страница 13: ...11 Wiring Diagrams MacroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Wiring Airlynk...

Страница 14: ...get to the next digit press the left or right arrows When you are done editing press OK to set the value NOTE The fans will be auto discovered each time the PLC is powered on Setting the fans through...

Страница 15: ...s needed to operate the fans through BACnet MSTP Proto Protocol BACn for BACnet MSTP Baud Baudrate of the protocol Addr Address of the PLC Data Data bit number Pari Parity Nul None Odd Eve Even Stop S...

Страница 16: ...k on PLC is a symbol that indicates that a product has passed a series of rigorous tests conducted by an independent laboratory which verifies that the product correctly implements the BACnet features...

Страница 17: ...wser referred to in this manual as the Web Configurator Select the device s from a drop down list of known profiles and assign at the stated Modbus address BACnet Setup 2 Configuring Device Communicat...

Страница 18: ...ns to PLC CN1 Device Pins PLC Pin Pin Assignment CN1 Pin RS 485 Pin1 RS 485 2 Pin RS 485 Pin 2 RS 485 2 Pin GND Pin 3 RS 485 2 GS Figure 3 Power and RS 485 Connections ref pg 10 4 Wiring Field Port to...

Страница 19: ...gies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Interfacing PLC To Devices cont 5 Ethernet Control CN20 6 Power up PLC CN10 Power to PLC PLC Pin Pin Assignment CN10 P...

Страница 20: ...rent IP Networks assign a static IP Address to the PC on the 192 168 1 xxx network For instructions on how to navigate your operating system to set up an IP address and subnet mask contact your system...

Страница 21: ...s the speed of fan 11 0 100 12 FanSpeed12 Sets the speed of fan 12 0 100 13 FanSpeed13 Sets the speed of fan 13 0 100 14 FanSpeed14 Sets the speed of fan 14 0 100 15 FanSpeed15 Sets the speed of fan 1...

Страница 22: ...ets the direction of fan 13 0 Off 1 Forward 2 Reverse 44 FanDir14 Sets the direction of fan 14 0 Off 1 Forward 2 Reverse 45 FanDir15 Sets the direction of fan 15 0 Off 1 Forward 2 Reverse 46 FanDir16...

Страница 23: ...tput current of fan 13 0 1 RPM AVD 0 1A VFD 74 FanRPM14 Shows the RPM output current of fan 14 0 1 RPM AVD 0 1A VFD 75 FanRPM15 Shows the RPM output current of fan 15 0 1 RPM AVD 0 1A VFD 76 FanRPM16...

Страница 24: ...fan 11 102 FanFault12 Displays the fault of fan 12 103 FanFault13 Displays the fault of fan 13 104 FanFault14 Displays the fault of fan 14 105 FanFault15 Displays the fault of fan 15 106 FanFault16 Di...

Страница 25: ...er of fan 16 8 24ft 137 FanSize17 Sets the diameter of fan 17 8 24ft 138 FanSize18 Sets the diameter of fan 18 8 24ft 139 FanSize19 Sets the diameter of fan 19 8 24ft 140 FanSize20 Sets the diameter o...

Страница 26: ...Hub Frame Standard Electrical1 Motor Electrical Controls Remote Labor Y Series Lifetime 3 Years 1 Year Z Series Lifetime 2 Years 1 Year AirVolution D 780 Lifetime 3 Years 1 Year AirVolution D 550 Lif...

Страница 27: ...s Please call MacroAir Fans for Technical Support of the AirLynk product Support Contact Information MacroAir Fans 794 S Allen Street San Bernardino CA 92408 MacroAir Fans Service 866 668 3247 Email t...

Страница 28: ...794 South Allen Street San Bernardino CA 92408 MacroAir AirLynk 866 668 3247 is UL Listed Macroairfans com...

Отзывы: