Appendix A. Control Points, cont.

 

AI 

Name 

Description 

Values 

121 

FanSize1 

Sets the diameter of fan 1 

8-24ft 

122 

FanSize2 

Sets the diameter of fan 2 

8-24ft 

123 

FanSize3 

Sets the diameter of fan 3 

8-24ft 

124 

FanSize4 

Sets the diameter of fan 4 

8-24ft 

125 

FanSize5 

Sets the diameter of fan 5 

8-24ft 

126 

FanSize6 

Sets the diameter of fan 6 

8-24ft 

127 

FanSize7 

Sets the diameter of fan 7 

8-24ft 

128 

FanSize8 

Sets the diameter of fan 8 

8-24ft 

129 

FanSize9 

Sets the diameter of fan 9 

8-24ft 

130 

FanSize10 

Sets the diameter of fan 10 

8-24ft 

131 

FanSize11 

Sets the diameter of fan 11 

8-24ft 

132 

FanSize12 

Sets the diameter of fan 12 

8-24ft 

133 

FanSize13 

Sets the diameter of fan 13 

8-24ft 

134 

FanSize14 

Sets the diameter of fan 14 

8-24ft 

135 

FanSize15 

Sets the diameter of fan 15 

8-24ft 

136 

FanSize16 

Sets the diameter of fan 16 

8-24ft 

137 

FanSize17 

Sets the diameter of fan 17 

8-24ft 

138 

FanSize18 

Sets the diameter of fan 18 

8-24ft 

139 

FanSize19 

Sets the diameter of fan 19 

8-24ft 

140 

FanSize20 

Sets the diameter of fan 20 

8-24ft 

141 

FanSize21 

Sets the diameter of fan 21 

8-24ft 

142 

FanSize22 

Sets the diameter of fan 22 

8-24ft 

143 

FanSize23 

Sets the diameter of fan 23 

8-24ft 

144 

FanSize24 

Sets the diameter of fan 24 

8-24ft 

145 

FanSize25 

Sets the diameter of fan 25 

8-24ft 

146 

FanSize26 

Sets the diameter of fan 26 

8-24ft 

147 

FanSize27 

Sets the diameter of fan 27 

8-24ft 

148 

FanSize28 

Sets the diameter of fan 28 

8-24ft 

149 

FanSize29 

Sets the diameter of fan 29 

8-24ft 

150 

FanSize30 

Sets the diameter of fan 30 

8-24ft 

151 

AllFanDir 

Sets the direction of all the fans 

0-Off 1-Forward 2-Reverse 

152  AllFanSpeed  Sets the speed of all the fans 

0-100% 

153 

AllFanSend 

Sends the all fan speed and direction 

1 to send 

154 

FanOn 

Select individual fan to set 

Fan 1-30 

155 

FanDir 

Set the direction of the selected fan 

0-Off 1-Forward 2-Reverse 

156 

FanSpeed 

Set the speed of the selected fan 

0-100% 

157 

FanSend 

Send the speed & direction of the selected fan 

1 to send 

 

Содержание AirLynk BACnet

Страница 1: ...Operation Manual MacroAir AirLynk BACnet...

Страница 2: ......

Страница 3: ...k Wiring Instructions 5 Repeater Install for 370 Fans 6 Network Wiring Requirements Daisy Chain 7 Improper Wiring Configuration Proper Wiring Configuration 8 Excess Cable at Connection Point 9 Wiring...

Страница 4: ...Read and understand this manual before installing or operating a fan unit Installation adjustment repair and maintenance must be performed by qualified personnel ATTENTION Code Compliance The user is...

Страница 5: ...r customizes fans to operate in a network by Addressing the fans and For 370 Fans Supplying an additional length of CAT5 Note For 370 Fans Repeaters Isolators must be added every 5 fans for stability...

Страница 6: ...Introduction MacroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 4 AirLynk Enclosure Dimensions Components...

Страница 7: ...roAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Network Wiring Instructions Refer to the appropriate fan installation manual for specific networking ins...

Страница 8: ...croairfans com Rev Date 071519 Repeater Install for 370 Fans Repeater Isolator The Repeater Isolator boosts the signal along the network preventing signal loss and minimizes noise on the line Repeater...

Страница 9: ...tromagnetic interference For 370 Fans Ground the shielding and drain wire at only one point of the cable run Add Repeaters Isolators 1 5fans Daisy Chain Networked MacroAir fans must be connected in on...

Страница 10: ...acroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Improper Wiring Configuration End of Line x3 End of Line x8 Proper Wiring Config...

Страница 11: ...ypical industrial commercial environment extra cable should not be coiled up as the coil itself will create noise interference in the communication signal There should be no more than two feet of exce...

Страница 12: ...chnologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Wiring CAT5E Pin Out CAT5E B to MacroAir Equipment Pin Out Note For Fire Alarm assignment on existing networks u...

Страница 13: ...11 Wiring Diagrams MacroAir AirLynk 2019 MacroAir Technologies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Wiring Airlynk...

Страница 14: ...get to the next digit press the left or right arrows When you are done editing press OK to set the value NOTE The fans will be auto discovered each time the PLC is powered on Setting the fans through...

Страница 15: ...s needed to operate the fans through BACnet MSTP Proto Protocol BACn for BACnet MSTP Baud Baudrate of the protocol Addr Address of the PLC Data Data bit number Pari Parity Nul None Odd Eve Even Stop S...

Страница 16: ...k on PLC is a symbol that indicates that a product has passed a series of rigorous tests conducted by an independent laboratory which verifies that the product correctly implements the BACnet features...

Страница 17: ...wser referred to in this manual as the Web Configurator Select the device s from a drop down list of known profiles and assign at the stated Modbus address BACnet Setup 2 Configuring Device Communicat...

Страница 18: ...ns to PLC CN1 Device Pins PLC Pin Pin Assignment CN1 Pin RS 485 Pin1 RS 485 2 Pin RS 485 Pin 2 RS 485 2 Pin GND Pin 3 RS 485 2 GS Figure 3 Power and RS 485 Connections ref pg 10 4 Wiring Field Port to...

Страница 19: ...gies Toll Free 866 668 3247 Fax 909 890 2313 www macroairfans com Rev Date 071519 Interfacing PLC To Devices cont 5 Ethernet Control CN20 6 Power up PLC CN10 Power to PLC PLC Pin Pin Assignment CN10 P...

Страница 20: ...rent IP Networks assign a static IP Address to the PC on the 192 168 1 xxx network For instructions on how to navigate your operating system to set up an IP address and subnet mask contact your system...

Страница 21: ...s the speed of fan 11 0 100 12 FanSpeed12 Sets the speed of fan 12 0 100 13 FanSpeed13 Sets the speed of fan 13 0 100 14 FanSpeed14 Sets the speed of fan 14 0 100 15 FanSpeed15 Sets the speed of fan 1...

Страница 22: ...ets the direction of fan 13 0 Off 1 Forward 2 Reverse 44 FanDir14 Sets the direction of fan 14 0 Off 1 Forward 2 Reverse 45 FanDir15 Sets the direction of fan 15 0 Off 1 Forward 2 Reverse 46 FanDir16...

Страница 23: ...tput current of fan 13 0 1 RPM AVD 0 1A VFD 74 FanRPM14 Shows the RPM output current of fan 14 0 1 RPM AVD 0 1A VFD 75 FanRPM15 Shows the RPM output current of fan 15 0 1 RPM AVD 0 1A VFD 76 FanRPM16...

Страница 24: ...fan 11 102 FanFault12 Displays the fault of fan 12 103 FanFault13 Displays the fault of fan 13 104 FanFault14 Displays the fault of fan 14 105 FanFault15 Displays the fault of fan 15 106 FanFault16 Di...

Страница 25: ...er of fan 16 8 24ft 137 FanSize17 Sets the diameter of fan 17 8 24ft 138 FanSize18 Sets the diameter of fan 18 8 24ft 139 FanSize19 Sets the diameter of fan 19 8 24ft 140 FanSize20 Sets the diameter o...

Страница 26: ...Hub Frame Standard Electrical1 Motor Electrical Controls Remote Labor Y Series Lifetime 3 Years 1 Year Z Series Lifetime 2 Years 1 Year AirVolution D 780 Lifetime 3 Years 1 Year AirVolution D 550 Lif...

Страница 27: ...s Please call MacroAir Fans for Technical Support of the AirLynk product Support Contact Information MacroAir Fans 794 S Allen Street San Bernardino CA 92408 MacroAir Fans Service 866 668 3247 Email t...

Страница 28: ...794 South Allen Street San Bernardino CA 92408 MacroAir AirLynk 866 668 3247 is UL Listed Macroairfans com...

Отзывы: