E6
TECHNICAL DETAILS - OIL PUMP ASSEMBLY
SAFETY INSTRUCTIONS
When the pump is connected to the compressed air supply:
1. The compressed air must be filtered to avoid dust and moisture into pump.
2. The max compressed air pressure must not exceed 1.0Mpa/150psi.
3. To deliver oil, press the knob on the delivery pistol; delivery stops when the knob is released
but the whole system remains under pressure.
4. Position the pistol so that the circuit can’t open accidentally. Otherwise oil could leak onto
the ground.
5. Never point the pistol at people or object.
6. Press the pistol knob.
7. Always cut off the air supply after use so that oil can’t leak out in case one of the pump’s
components should break.
8. Use only original spare parts in case the pump has to be repaired or its components have to
be replaced.
9. Empty all the oil from the pump in case it has to be disposed of.
10. When not in use, turn off compressed air to stop pump.
11. Do not use the pump near open flames. Do not smoke during this operation.
12. Wear oil-proof gloves.
13. Do not throw the oil away. Used oil has to be disposed of according to national
environmental regulations.
14. The pumps can be used only to deliver lubricants, used oil or antifreeze liquids. Do not use
the pump for any other substance.
THE MANUAL OF OIL PUMP
Read the following precautions and instructions before you begin assembly or using.
Failure to comply with these instructions could result in personal injury or property damage.
Keep these instructions in a convenient location for future reference.
IMPORTANT NOTE
The guarantee will be void if the pump has been altered in any way.
PROFILE
Oil pumps can be used to transfer lubrication oil, waste oil and antifreeze liquids.
This manual is applicable to the following pump only, please confirm your pump is included.
Item No.
Drum Application
Pressure Ration
Air Inlet Pressure
Max.fluid Pressure
Air Motor Effective Diameter
Air Consumption (Per Minute)
Max. Free Flow Rate (Per Minute)
Suction Tube Diameter
Suction Tube Length
Suction Tube Material
Air Inlet Connection
Oil Outlet Connection
OP165-1-001
13-16gallon
5:1
30~150psi
750psi
2-1/2"
2.8CFM @150psi
4gallon
1-5/8"
28-3/4"
Carbon Steel
1/4"NPT female
1/2"NPT male
OP585-1-001
48-58gallon
5:1
30~150psi
750psi
2-1/2"
2.8CFM @150psi
4gallon
1-5/8"
37"
Carbon Steel
1/4"NPT female
1/2"NPT male