background image

E6

TECHNICAL DETAILS - OIL PUMP ASSEMBLY

SAFETY INSTRUCTIONS

When the pump is connected to the compressed air supply:

1. The compressed air must be filtered to avoid dust and moisture into pump.

2. The max compressed air pressure must not exceed 1.0Mpa/150psi.

3. To deliver oil, press the knob on the delivery pistol; delivery stops when the knob is released 

but the whole system remains under pressure.

4. Position the pistol so that the circuit can’t open accidentally. Otherwise oil could leak onto 

the ground.

5. Never point the pistol at people or object.

6. Press the pistol knob.

7. Always cut off the air supply after use so that oil can’t leak out in case one of the pump’s 

components should break.

8. Use only original spare parts in case the pump has to be repaired or its components have to 

be replaced.

9. Empty all the oil from the pump in case it has to be disposed of.

10. When not in use, turn off compressed air to stop pump.

11. Do not use the pump near open flames. Do not smoke during this operation.

12. Wear oil-proof gloves.

13. Do not throw the oil away. Used oil has to be disposed of according to national 

environmental regulations.

14. The pumps can be used only to deliver lubricants, used oil or antifreeze liquids. Do not use 

the pump for any other substance.

THE MANUAL OF OIL PUMP

Read the following precautions and instructions before you begin assembly or using. 

Failure to comply with these instructions could result in personal injury or property damage. 

Keep these instructions in a convenient location for future reference.

IMPORTANT NOTE

The guarantee will be void if the pump has been altered in any way.

PROFILE

Oil pumps can be used to transfer lubrication oil, waste oil and antifreeze liquids.

This manual is applicable to the following pump only, please confirm your pump is included.

Item No.

Drum Application

Pressure Ration

Air Inlet Pressure

Max.fluid Pressure

Air Motor Effective Diameter

Air Consumption (Per Minute)

Max. Free Flow Rate (Per Minute)

Suction Tube Diameter

Suction Tube Length

Suction Tube Material

Air Inlet Connection

Oil Outlet Connection

OP165-1-001

13-16gallon
5:1
30~150psi
750psi
2-1/2"
2.8CFM @150psi
4gallon
1-5/8"
28-3/4"
Carbon Steel
1/4"NPT female
1/2"NPT male

OP585-1-001

48-58gallon
5:1
30~150psi
750psi
2-1/2"
2.8CFM @150psi
4gallon
1-5/8"
37"
Carbon Steel
1/4"NPT female
1/2"NPT male

Содержание M3OKT516-KIT

Страница 1: ...ilure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required Kee...

Страница 2: ...ment and do not use this equipment for a purpose for which it was not intended 4 Check for damaged parts Before using this product carefully check that it will operate properly and perform its intende...

Страница 3: ...ight prepaid to the distributor or their designated service depot 3 The warranty does not cover damage caused by accident misuse or faulty installation 4 The product must be installed and maintained i...

Страница 4: ...art No 1 according to its instruction manual 1 Install the pump part No 2 into the corresponding fixing hole of the trolley Step 1 Step 2 1 Tighten the female thread of delivery hose part No 3 with th...

Страница 5: ...E3 EXPLODED VIEW AND DETAILS QTY 1 1 1 1 Description Trolley Oil Pump Delivery Hose Assembly Oil Control Valve Wearing parts Part No 1 2 3 4 M3OKT516 KIT M3OKT555 KIT 2 1 3 4 2 3 1 4...

Страница 6: ...n Part No 1 2 3 4 5 6 7 8 9 10 Description Screw Trolley Top Handle Handle Cover Drum Support Adjustable Cover Adjustable Pole Hexagon Bolt Handle Wheel Accessory Q ty 1 1 1 1 1 1 1 2 3 1 Part No 11 1...

Страница 7: ...holder support Handle Pump support Hexagon screw set Stopper Accessories support Acom nut Washer Q ty 1 1 1 2 3 1 1 2 2 Part No 10 11 12 13 14 15 16 17 Description A swivelling wheel Hexagon bolt Was...

Страница 8: ...il has to be disposed of according to national environmental regulations 14 The pumps can be used only to deliver lubricants used oil or antifreeze liquids Do not use the pump for any other substance...

Страница 9: ...l with SAE 20 SAE 30 or antifreeze oil for extreme conditions when necessary NOTE The user should perform only routine maintenance operations such as filters silencers cleaning with the pump in order...

Страница 10: ...line 6 A cut off switch can enable the operator to stop the pump at any given moment by cutting the air supply off between the pump and the compressed air line 7 Switch on all switch WALL INSTALLED P...

Страница 11: ...om the stub pump screw the extension tube on W top connection then screw filter and foot valve on the extension tube foot connection end Connect the Pump with Other Accessories Part List QTY 1 1 1 1 1...

Страница 12: ...E10 EXPLODED AND PARTS LIST 46 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 18 3 19 20 21 22 23 23 24 25 26 27 31 28 29 30 33 34 35 36 37 38 39 40 41 42 43 44 45 46 32...

Страница 13: ...26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 46 Description Circlip Type A Oil inlet Washer Guide belt Piston sealing Base O ring Circlip Type A Shaft Connector Elastic pin Bearing...

Страница 14: ...cause serious injury 1 Fluid injected into the skin might look like just a cut but it is a serious injury Get immediate medical attention 2 Do not point the valve at anyone or at any part of the body...

Страница 15: ...rk your way toward the pump 5 Slowly open the shut off valve at the dispense position Flush out a sufficient amount of oil to ensure that the entire system is clean and close the valve 6 Repeat step 5...

Страница 16: ...meter from damage due to impact Meters are factory sealed to keep moisture and dirt out 2 To prevent line contamination which can cause equipment malfunction or damaged flush the lines before you inst...

Страница 17: ...ressure can be injected through the skin and cause serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the pressure relief procedure whenever you 1 Are...

Страница 18: ...distributor for repair or replacement Replace the o ring If the problem remains contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged...

Страница 19: ...g Filter Adapter O ring Meter Holder Meter Cover Rubber Protector Q ty 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Part No 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 17 3 18 3 19 3 20 3 21 4 Des...

Страница 20: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: