E16
TROUBLE SHOOTING GUIDE
Relieve the pressure before you check or repair the dispensing valve. Be sure all other valves
and controls and the pump are operating properly.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always
follow the pressure relief procedure.
Problem
Slow or no fluid flow.
Oil leaks from swivel.
Oil drips from nozzle.
Valve leaks.
Leakage from meter.
No Display.
Wrong Reading.
Problem
Filter is clogged, or pump pressure is low,
or shut-off valve is not fully open, or
foreign materialis jammed in the
metering element.
Swivel is loose.
O-ring is worn or damaged.
Nozzle is damaged or obstructed.
O-rings or valve seat are worn or damaged.
O-ring damaged.
Loosing Battery.
Battery out of power.
correction coefficient error.
Solution
1. Relief the pressure.
2. Loose swivel fitting, clean or replace the filter.
3. If the problem remains, contact your
distributor for repair or replacement.
Torque the swivel.
If the problem remains, contact your distributor
for repair or replacement.
Replace the o-ring.
If the problem remains, contact your distributor
for repair or replacement.
Inspect the nozzle for damage or obstructions,
and replace if damaged.
If the problem remains, contact your distributor
for repair or replacement.
Replace the o-rings and/or the valve seat.
If the problem remains, contact your distributor
for repair or replacement.
1. Get the meter off from the dispense system.
2. Take off the protector.
3. Loosing four the socket head cap screws on
the cover of the meter.
4. Loosing eight the hex bolts on the bottom of
the meter.
5. Take off the seat.
6. Check the o-ring, replacing the o-ring if it is
damaged.
7. After replacing the o-ring, assemble the meter
and fix it back to the dispense system.
1. Get the meter off from the dispense system.
2. Take off the protector.
3. Take off the labels sticks on the bottom of the
meter.
4. Loosing the five socket head cap screws on
the bottom of the meter.
5. Take off the seat.
6. Check the battery, replacing the battery if it is
out of power.
7. After replacing the battery, assemble the
meter and fix it back to the dispense system.
Reset the correction factor (follow the
instructions on Page 6).