4. Apply thread sealant to the male threads of the hose fitting, thread the hose fitting into the

swivel, and tighten firmly.

5. Thread the new nozzle or nozzle adapter onto the extension, and tighten firmly.

6. Open all dispense position shut-off valves, and start the pump to pressurize the system. See

the Operation section for proper operation.

7. For metered dispense valves, to ensure dispensing accuracy, purge all air from the fluid

lines and dispense valves before you use them.

Grounding

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground all system components per local and national 

electrical codes.

Refer to the user manuals for the pump and other system components to ground the following:

1. Pump: Follow manufacture’s recommendations.

2. Air and Fluid hoses: Use only grounded hoses.

3. Air compressor: Follow manufacture’s recommendations.

4. Fluid supply container: Follow your local code.

5. To maintain grounding continuity when flushing or relieving pressure, always hold a metal

part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

OPERATION

CAUTION

:

1. Never operate the meter with the plastic cover removed. The cover protects the meter from

damage due to impact. Meters are factory sealed to keep moisture and dirt out.

2. To prevent line contamination, which can cause equipment malfunction or damaged, flush

the lines before you install this equipment in the system.

Display and Button Usage

To Activate the Digital Display

1. Press the RESET key pad to clear the meter before starting a new dispense cycle. This is the

best way to activate the meter, because it also clears the quantity of the last dispense cycle.

2. The digital display can also be activated by pressing the MENU key pad or by running fluid

through the meter.

Calibrating Automatically

1. Press Reset key for 1 second and Area 1 shows .000 L;

2. Keep running fluid through the meter until the fluid running out of the certain measuring

cylinder. The display will show certain value as *.**L, press the Menu key for 3 seconds. The

meter will enter instrument calibration mode and Area 1 shows 00*.**L;

3. Press Menu key to move the flashing digital, press Reset key to choose number, enter the

fluid volume and press Menu key again for 3 seconds, then exit the calibration mode. The

calibration settled.

AREA 1: FOR LAST DISPENSE CYCLE

AREA 2: FOR MEASUREMENT UNITS

AREA 3: FOR ACCUMULATED
TOTAL

AREA 4: FOR BATTERY
CAPACITY
Notes: It will flashing when
battery voltage less than 3.3V;

Menu: MOVING THE NUMBERS FOR
ADJUSTING THE CALIBRATION AND
CHOOSING THE UNITS

Reset: CHOOSING THE UNITS AND SETTING
CORRECTION FACTOR

Содержание M3OKT516-KIT

Страница 1: ...ilure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required Kee...

Страница 2: ...ment and do not use this equipment for a purpose for which it was not intended 4 Check for damaged parts Before using this product carefully check that it will operate properly and perform its intende...

Страница 3: ...ight prepaid to the distributor or their designated service depot 3 The warranty does not cover damage caused by accident misuse or faulty installation 4 The product must be installed and maintained i...

Страница 4: ...art No 1 according to its instruction manual 1 Install the pump part No 2 into the corresponding fixing hole of the trolley Step 1 Step 2 1 Tighten the female thread of delivery hose part No 3 with th...

Страница 5: ...E3 EXPLODED VIEW AND DETAILS QTY 1 1 1 1 Description Trolley Oil Pump Delivery Hose Assembly Oil Control Valve Wearing parts Part No 1 2 3 4 M3OKT516 KIT M3OKT555 KIT 2 1 3 4 2 3 1 4...

Страница 6: ...n Part No 1 2 3 4 5 6 7 8 9 10 Description Screw Trolley Top Handle Handle Cover Drum Support Adjustable Cover Adjustable Pole Hexagon Bolt Handle Wheel Accessory Q ty 1 1 1 1 1 1 1 2 3 1 Part No 11 1...

Страница 7: ...holder support Handle Pump support Hexagon screw set Stopper Accessories support Acom nut Washer Q ty 1 1 1 2 3 1 1 2 2 Part No 10 11 12 13 14 15 16 17 Description A swivelling wheel Hexagon bolt Was...

Страница 8: ...il has to be disposed of according to national environmental regulations 14 The pumps can be used only to deliver lubricants used oil or antifreeze liquids Do not use the pump for any other substance...

Страница 9: ...l with SAE 20 SAE 30 or antifreeze oil for extreme conditions when necessary NOTE The user should perform only routine maintenance operations such as filters silencers cleaning with the pump in order...

Страница 10: ...line 6 A cut off switch can enable the operator to stop the pump at any given moment by cutting the air supply off between the pump and the compressed air line 7 Switch on all switch WALL INSTALLED P...

Страница 11: ...om the stub pump screw the extension tube on W top connection then screw filter and foot valve on the extension tube foot connection end Connect the Pump with Other Accessories Part List QTY 1 1 1 1 1...

Страница 12: ...E10 EXPLODED AND PARTS LIST 46 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 18 3 19 20 21 22 23 23 24 25 26 27 31 28 29 30 33 34 35 36 37 38 39 40 41 42 43 44 45 46 32...

Страница 13: ...26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 46 Description Circlip Type A Oil inlet Washer Guide belt Piston sealing Base O ring Circlip Type A Shaft Connector Elastic pin Bearing...

Страница 14: ...cause serious injury 1 Fluid injected into the skin might look like just a cut but it is a serious injury Get immediate medical attention 2 Do not point the valve at anyone or at any part of the body...

Страница 15: ...rk your way toward the pump 5 Slowly open the shut off valve at the dispense position Flush out a sufficient amount of oil to ensure that the entire system is clean and close the valve 6 Repeat step 5...

Страница 16: ...meter from damage due to impact Meters are factory sealed to keep moisture and dirt out 2 To prevent line contamination which can cause equipment malfunction or damaged flush the lines before you inst...

Страница 17: ...ressure can be injected through the skin and cause serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the pressure relief procedure whenever you 1 Are...

Страница 18: ...distributor for repair or replacement Replace the o ring If the problem remains contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged...

Страница 19: ...g Filter Adapter O ring Meter Holder Meter Cover Rubber Protector Q ty 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Part No 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 17 3 18 3 19 3 20 3 21 4 Des...

Страница 20: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: