background image

WARNING: Each device with different max working pressure. To reduce the risk 

of exceed pressure. Make sure the max work pressure for each device. Rated 

pressure in the system can not exceed the max pressure of any device. Or there 

will be burst, explosion, malfunction, serious damage.

Remind: 

Pump can not operate with empty load. Or the speed will be very fast which will 

self-damage.

If acceleration is too fast or running very slow, Should stop operation and check that if there is 

enough oil in the barrel. If there is insufficient oil, change the trolley and initialize the whole 

system.

Startup

• If there is several pump in the whole system, please use control valve to dispatch the air.

• Open the main control valve.

• Open the oil valve which with effective grounding with the trolley. Keep the connecting of the 

metal forboth oil valve and trolley. Open the cut-off valve, pump start to work. When the pump 

is stable. Close theoil valve.

• If there are several pumps in the whole system, startup for each pump step by step with 

above instruction.

• To get perfect result, set up the min air pressure for each device.

• Pump can not operate under empty load.

• Relief pressure before close the pump.

TROUBLE SHOOTING

WARNING: To reduce the risk of serious injury whenever you are instructed to 

relieve pressure. Do not remove silencer, or it may cause finger be injury.

 Before check and maintain, pay more attention of the relieve of pressure.

Ordinary problems, reason and solution

E4

TECHNICAL

DETAILS

EXPLODED AND

PARTS LIST

INSTALLATION

TROUBLE  SHOOTING 

SAFETY

INSTRUCTIONS

OPERATION

LIMITED

WARRANTY

WALL

INSTALLED

Problem
Pump fails to operate

Continuous air exhaust

Erratic pump operation

Pump operates, but output

low on both strokes

Leakage from silencer

Solution

Cause

Inadequate air supply pressure or 

restricted air lines
Closed or clogged dispensing valve
Clogged fluid lines, hoses, valves, etc
Damaged air motor
Exhausted fluid supply
Worn or damaged air motor gas-kit, 

packing, seal, etc.
Exhausted fluid supply
Held open or worn intake valve or 

piston packing
Hose damaged
Piston damaged
Seal O-ring damaged
Hose, valve or other device block
O-ring damaged

Increase air supply; clear

Open; clear
Clear
Service air motor
Refill and re-prime or flush
Service air motor

Refill and re-prime or flush
Clear; service

Change hose
Change piston
Change O-ring
Relieve pressure
Change O-ring

Содержание HVOP3

Страница 1: ...operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when...

Страница 2: ...ts Before using this product carefully check that it will operate properly and perform its intended function Check for damaged parts and any other conditions that may affect the operation of this prod...

Страница 3: ...r lift pump during use Comply with all applicable local state and national fire electrical and safety regulations SKIN INJECTION HAZARD Fluid from the dispensing valve leaks or ruptured components can...

Страница 4: ...on to avoid the buildup of flammable fumes from solvents or the fluid dispensed Keep the dispensing area free of debris including solvent rags and gasoline Do not smoke in the dispensing area GROUNDIN...

Страница 5: ...essure relief by manual Pump is under pressure To reduce the risk of serious injury from pressurized fluid accidental spray from the valve or splashing fluid follow this procedure whenever you Are ins...

Страница 6: ...for each device Pump can not operate under empty load Relief pressure before close the pump TROUBLE SHOOTING WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressu...

Страница 7: ...for a period of 36 months from date of purchase but not including wearing parts 2 Manufacturer s liability is limited to replacement or repair of defective material within the warranty period when ret...

Страница 8: ...XPLODED AND PARTS LIST INSTALLATION TROUBLE SHOOTING SAFETY INSTRUCTIONS OPERATION LIMITED WARRANTY WALL INSTALLED 37 1 2 3 4 20 22 23 21 24 25 26 28 29 30 31 32 33 34 35 36 27 38 39 40 41 42 43 44 45...

Страница 9: ...Rod Sealing O ring O ring O ring Part No 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 Description Fixed Block O ring Quick Connector Pump Body Screw Screw Silencer Oil in...

Страница 10: ...EXPLODED AND PARTS LIST INSTALLATION TROUBLE SHOOTING SAFETY INSTRUCTIONS OPERATION LIMITED WARRANTY WALL INSTALLED 1 2 3 4 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 4...

Страница 11: ...ing Rod Sealing O ring O ring Part No 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Description O ring Fixed Block O ring Quick Connector Pump Body Screw Screw Silencer Oi...

Страница 12: ...he bracket 4 3 Connect the flexible suction tubes 6 to the pump using the clamp provided 4 Cnnect the rigid suction 8 to the end of the flexible suction tube 6 using the elastic clamp provided 5 Put t...

Отзывы: