WARNING: Each device with different max working pressure. To reduce the risk
of exceed pressure. Make sure the max work pressure for each device. Rated
pressure in the system can not exceed the max pressure of any device. Or there
will be burst, explosion, malfunction, serious damage.
Remind:
Pump can not operate with empty load. Or the speed will be very fast which will
self-damage.
If acceleration is too fast or running very slow, Should stop operation and check that if there is
enough oil in the barrel. If there is insufficient oil, change the trolley and initialize the whole
system.
Startup
• If there is several pump in the whole system, please use control valve to dispatch the air.
• Open the main control valve.
• Open the oil valve which with effective grounding with the trolley. Keep the connecting of the
metal forboth oil valve and trolley. Open the cut-off valve, pump start to work. When the pump
is stable. Close theoil valve.
• If there are several pumps in the whole system, startup for each pump step by step with
above instruction.
• To get perfect result, set up the min air pressure for each device.
• Pump can not operate under empty load.
• Relief pressure before close the pump.
TROUBLE SHOOTING
WARNING: To reduce the risk of serious injury whenever you are instructed to
relieve pressure. Do not remove silencer, or it may cause finger be injury.
Before check and maintain, pay more attention of the relieve of pressure.
Ordinary problems, reason and solution
E4
TECHNICAL
DETAILS
EXPLODED AND
PARTS LIST
INSTALLATION
TROUBLE SHOOTING
SAFETY
INSTRUCTIONS
OPERATION
LIMITED
WARRANTY
WALL
INSTALLED
Problem
Pump fails to operate
Continuous air exhaust
Erratic pump operation
Pump operates, but output
low on both strokes
Leakage from silencer
Solution
Cause
Inadequate air supply pressure or
restricted air lines
Closed or clogged dispensing valve
Clogged fluid lines, hoses, valves, etc
Damaged air motor
Exhausted fluid supply
Worn or damaged air motor gas-kit,
packing, seal, etc.
Exhausted fluid supply
Held open or worn intake valve or
piston packing
Hose damaged
Piston damaged
Seal O-ring damaged
Hose, valve or other device block
O-ring damaged
Increase air supply; clear
Open; clear
Clear
Service air motor
Refill and re-prime or flush
Service air motor
Refill and re-prime or flush
Clear; service
Change hose
Change piston
Change O-ring
Relieve pressure