Mackie UP4061 Скачать руководство пользователя страница 8

UP4000 – 8

Internal Settings

There is one setting that can be changed inside

the UP4000 Series Amplifier. This setting should be
made prior to installation.

CAUTION:

 These servicing instructions

are for use by qualified personnel only. To
avoid electric shock, do not perform any

servicing other than that contained in the Operating
Instructions unless you are qualified to do so.
Refer all servicing to qualified service personnel.
Make sure the power is off and the power cord
disconnected before removing the top cover to gain
access to the inside of the UP4000 Series.

STANDBY MODE

Jumper J1 on the input board allows you to

enable the Standby function. Standby mode is
disabled by default. You must change jumper J1 on
the input board to enable the Standby function.

Thermal Considerations

IMPORTANT:

 The UP4000 Series amplifier is

convection cooled rather than fan cooled. Heat is
drawn away from the amplifier by the heatsink and
radiated through the cooling vents in the top cover.
When installing the UP4000 Series, be sure to
allow sufficient air space around the top and rear of
the amplifier to allow adequate cooling for the
heatsink. 

Leave at least one rack space above and

below the UP4000 and at least 6 inches behind the
chassis to allow proper ventilation.

If the amplifier should overheat, a thermal

switch is activated that turns off the power
amplifier, allowing the heatsinks to cool down. The

ON

 indicator on the front panel will remain lit. Once

the amplifier has cooled to a safe operating
temperature, the thermal switch resets and
reactivates the amplifier. If this should occur,
identify the cause of the problem and take

corrective action (i.e.,
provide better
ventilation, install a fan
in the rack, make sure
the amplifier is not
overloaded by too low
of a load impedance or
by a short circuit on the
speaker line).

UP4000 Series Input Board Jumper

J1

1

2

3

STANDBY DISABLED
(DEFAULT)

STANDBY ENABLED

JP6

UP4000 SERIES

INPUT BOARD

AC Power Considerations

The UP4000 Series draw an average AC line

current as indicated on the following chart:

115VAC

230VAC

UP4060

1.5A

0.8A

UP4120

4.0A

2.0A

UP4160

4.8A

2.4A

Voltage Conversion

The UP4000 Series can be configured to operate

at 115 VAC or 230 VAC. Be sure the 

VOLTAGE

SELECTOR

 switch on the rear panel is set to the

correct position for the AC power supply being used.

115

VOLTAGE

SELECTOR

230

VOLTAGE

SELECTOR

Содержание UP4061

Страница 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Страница 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Страница 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Страница 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Страница 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Страница 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Страница 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Страница 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Страница 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Страница 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Страница 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Страница 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...

Отзывы: