Mackie UP4061 Скачать руководство пользователя страница 5

UP4000 – 5

Connect the appropriate 

POWER OUTPUT

voltage terminal to the "+" (HIGH) leg and the "0"
terminal to the "–" (LOW) leg of the distributed
speaker system.

The ground ( ) terminal is internally connected

to the chassis and safety ground on the AC linecord.

The

 PRIORITY

 terminal activates the priority

function for the 

BALANCED IN

 by using an external

normally-open switch to short-circuit the

 PRIORITY

terminal to the 

GND

 

 (ground) terminal. When the

PRIORITY

 function is enabled, the 

UNBALANCED IN

is muted (no signal from the 

UNBALANCED IN

 is

transmitted to the outputs).

This 

GND

 terminal is the common connection

point for 

BALANCED IN

 and 

PRIORITY

.

The 

BALANCED IN

 

terminals are the main input

for the amplifier and accept a balanced line-level
signal (0 dBu nominal). This input has a priority
function, which mutes the 

UNBALANCED IN

 signal

when the 

PRIORITY

 terminal is shorted to 

GND

.

The 

STAND BY

 terminal is used to turn on the

amplifier with a remote switch.

Note:

 Standby mode must first be activated by

moving a jumper (J1) on the input board (standby
mode is disabled by default). See "Internal Settings"
on page 8.

When the 

POWER

 switch is turned on, the amplifier

goes into standby mode. In this state, the amplifier
is on but signal is not allowed to pass. Shorting the

STAND BY

 terminal to the 

GND

 

 terminal with an

external switch causes the amplifier to become fully
operational.

The 

STANDBY GND

 terminal on the

COMMANDS

 terminal strip is the common

connection point for 

STAND BY

.

The 

OVERL. 300mA

 terminal is active whenever

the amplifier's overload protection circuit is
activated. This provides 18 VDC with a maximum
output capacity of 300mA for driving an auxiliary
relay or indicating LED.

The 

OVERL. GND

 terminal on the 

COMMANDS

terminal strip is the common connection point for

OVERL. 300mA

.

AC Protection Fuse protects the power supply

and amplifier circuitry. Replace only with same type
fuse.

Connect the supplied AC linecord to the IEC AC

Socket. The AC line fuse is contained in the socket,
behind the cover located at the bottom of the
socket. Replace only with same type fuse.

The 

VOLTAGE SELECTOR

 switch is used to

select the AC supply voltage for the amplifier. Move
the switch so the AC line voltage used appears on
the switch (DOWN for 115V, UP for 230V).

The 

H.P.

 switch activates a high-pass filter on the

balanced and unbalanced inputs, which attenuates
frequencies below 300Hz at 12 dB/octave.

The 

L.P.

 switch activates a low-pass filter on the

balanced and unbalanced inputs, which attenuates
frequencies above 7kHz at 12 dB/octave.

UNBALANCED IN

 

is an RCA jack that can be

used instead of the 

BALANCED IN

, or both can be

used with the 

PRIORITY

 function, which gives the

BALANCED IN

 priority over the 

UNBALANCED IN

.

PARALLEL OUT

 is an RCA jack that is in parallel

with the 

UNBALANCED IN

 jack for connecting to

the input of another power amplifier.

The 

SENSITIVITY

 switch adjusts the input

sensitivity of the 

UNBALANCED IN

 from 0 dB

(typical line-level signals) to 20 dB (for low-level
signals).

+

D.C. FUSE

115

0

50V

70V

100V

POWER OUTPUTS

0

25V

POWER INPUT

24V D.C.

COMMANDS

VOLTAGE

SELECTOR

POWER OUTPUTS

LINE

     50/60 Hz-115/230V

-

4

INPUT

0dB

20dB

ON

OFF

PRIORITY

GND

UNBALANCED IN

GND

H.P.

FILTER

BALANCED

IN

L.P.

STAND

BY

SENSITIVITY

GND

PARALLEL OUT

OVERL.

300mA.

max

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL • MADE IN ITALY • PATENTS PENDING • COPYRIGHT ©1999

SERIAL NUMBER

MANUFACTURING DATE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

CAUTION

AVIS:

 

RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

 THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE 

Содержание UP4061

Страница 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Страница 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Страница 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Страница 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Страница 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Страница 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Страница 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Страница 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Страница 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Страница 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Страница 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Страница 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...