Mackie UP4061 Скачать руководство пользователя страница 3

UP4000 – 3

2.

INTRODUCTION

KEY FEATURES

Balanced and Unbalanced Inputs

Balanced Input Priority Function

Unbalanced Line-Level Output

Convection Cooled Power Amplifier
UP4061:   60 Watts RMS
UP4121: 120 Watts RMS
UP4161: 160 Watts RMS

4

 Constant-Impedance Output

25V, 50V, 70V, and 100V Constant-Voltage Outputs

High-Pass and Low-Pass Filters

2 RU Rack-Mounting Kit

Automatic 24 VDC Backup Power Input

Part No. 910-142-30  Rev. A  10/01
© 2001 All Rights Reserved.  Mackie Industrial.  Printed in U.S.A.

The UP4000 Series Power Amplifiers are

designed for continuous duty in speech, music,
paging, and sound reinforcement applications in
churches, schools, offices, and other venues
demanding high performance, flexible features, and
rugged dependability.

Two discrete inputs with priority are provided.

The main program input is actively balanced and
terminated to a barrier strip connection on the rear
panel. The second input is unbalanced and terminated
to a single RCA connector. A contact closure will give
priority to the balanced input by muting the
unbalanced input. The unbalanced input features a
parallel output and 0 dB/20 dB sensitivity switch.

Output modes include 4

 constant impedance

and 25V, 50V, 70V, and 100V constant voltage. The
smart output stage is fully protected against
permanent damage caused by overloading, shorts,
and extreme temperatures. Activation of the
overload protection circuit turns on 18 VDC (300mA)
power at a barrier connector on the rear panel, which
may be used to drive a relay or indicating LED. The
UP4000 Series will operate on either 115 VAC or
230 VAC, 50/60Hz, as determined by the Voltage
Selector switch, and supplied by a detachable IEC
power cord. Insulated terminals to connect a backup
24 VDC battery are provided on the rear panel.
Switchover to DC is automatic. A programmable
stand-by mode allows the amplifier to be turned on
remotely with a contact closure.

The front panel provides a Master volume control,

and Low and High EQ controls. The control knobs
can be removed for security, and their recessed
shafts covered with the supplied inserts. LEDs
indicate power, stand-by mode, signal present at
the output, peak, and output overload. 12 dB/octave
Low and High shelving equalization with up to 12 dB
of boost or cut at 100Hz and 10kHz can be applied
to the output signal.

Accessories include a rack mounting kit.

Содержание UP4061

Страница 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Страница 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Страница 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Страница 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Страница 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Страница 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Страница 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Страница 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Страница 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Страница 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Страница 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Страница 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...

Отзывы: