Mackie UP4061 Скачать руководство пользователя страница 2

UP4000 – 2

CAUTION    

AVIS

RISK OF ELECTRIC 

SHOCK 

DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral 
triangle is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product's enclosure, that may be 
of sufficient magnitude to constitute a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle 
équilatéral est utilisé pour alerter l'utilisateur de la présence à 
l'intérieur du coffret de "voltage dangereux" non isolé d'ampleur 
suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to 
alert the user of the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est 
employé pour alerter les utilisateurs de la présence d'instructions 
importantes pour le fonctionnement et l'entretien (service) dans le 
livret d'instruction accompagnant l'appareil.

8.

 Power Sources — Connect the UP4000 to a power supply only of the type

described in these operation instructions or as marked on the rear panel.

9.

 Power Cord Protection — Route power supply cords so that they are not likely to be

walked upon or pinched by items placed upon or against them, paying particular attention
to cords at plugs, convenience receptacles, and the point where they exit the UP4000.

10.

 Object and Liquid Entry — Do not drop objects into or spill liquids into the inside

of the UP4000.

11.

 Damage Requiring Service — The UP4000 should be serviced only by qualified

service personnel when:

A.

 The power-supply cord or the plug has been damaged; or

B.

 Objects have fallen, or liquid has spilled into the UP4000; or

C.

 The UP4000 has been exposed to rain; or

D.

 The UP4000 does not appear to operate normally or exhibits a

marked change in performance; or

E.

 The UP4000 has been dropped, or its chassis damaged.

12.

 Servicing — The user should not attempt to service the UP4000 beyond those

means described in this operating manual. All other servicing should be referred to the
Mackie Service Department.

13.

 To prevent electric shock, do not use this polarized plug with an extension cord,

receptacle or other outlet unless the blades can be fully inserted to prevent blade
exposure.

Pour prévenir les chocs électriques ne pas utiliser cette fiche polariseé avec un
prolongateur, un prise de courant ou une autre sortie de courant, sauf si les lames
peuvent être insérées à fond sans laisser aucune pariie à découvert.

14.

 Grounding or Polarization — Precautions should be taken so that the grounding or

polarization means of the UP4000 is not defeated.

15.

 This apparatus does not exceed the Class A/Class B (whichever is applicable)

limits for radio noise emissions from digital apparatus as set out in the radio
interference regulations of the Canadian Department of Communications.

ATTENTION

 —Le présent appareil numérique n’émet pas de bruits radioélectriques

dépassant las limites applicables aux appareils numériques de class A/de class B (selon
le cas) prescrites dans le règlement sur le brouillage radioélectrique édicté par les
ministere des communications du Canada.

1. SAFETY INSTRUCTIONS

1.

 Read Instructions — Read all the safety and operation instructions before

operating the UP4000.

2.

 Retain Instructions — The safety and operating instructions should be kept for

future reference.

3.

 Heed Warnings — Follow all warnings on the UP4000 and in these operating

instructions.

4.

 Follow Instructions — Follow all operating and other instructions.

5.

 Water and Moisture — Do not use the UP4000 near water – for example, near a

bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming
pool, etc.

6.

  Ventilation — This UP4000 should be situated so that its location or position

does not interfere with its proper ventilation. For example, it should not be
situated on a bed, sofa, rug, or similar surface that may block any ventilation
openings, or placed in a built-in installation such as a bookcase or cabinet that
may impede the flow of air through ventilation openings.

7.

 Heat — Locate the UP4000 away from heat sources such as radiators, or other

devices which produce heat.

WARNING

 — To reduce the risk of fire or electric

shock, do not expose this appliance to rain or moisture.

TABLE OF CONTENTS

1.

SAFETY INSTRUCTIONS .......................................

2

2.

INTRODUCTION .....................................................

3

KEY FEATURES ................................................... 3

FRONT PANEL FEATURES ................................. 4

REAR PANEL FEATURES .................................... 4

3.

INSTALLATION .......................................................

6

APPLICATION DIAGRAM ................................... 6

CONNECTIONS ................................................... 7

INTERNAL SETTINGS ........................................ 8

AC POWER CONSIDERATIONS ......................... 8

THERMAL CONSIDERATIONS ........................... 8

4.

OPERATION ............................................................

9

USING THE BALANCED INPUT ......................... 9

USING THE UNBALANCED INPUT ................... 9

USING THE PARALLEL OUT .............................. 9

COMMANDS STANDBY ..................................... 9

POWER OUTPUTS .............................................. 9

POWER INPUT 24V D.C. ..................................... 9

5.

SPECIFICATIONS ..................................................

10

UP4000 SERIES BLOCK DIAGRAM ................. 10

UP4000 SERIES SPECIFICATIONS ................... 10

6.

SERVICE INFORMATION .....................................

11

Содержание UP4061

Страница 1: ...NDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RE...

Страница 2: ...other servicing should be referred to the Mackie Service Department 13 To prevent electric shock do not use this polarized plug with an extension cord receptacle or other outlet unless the blades can...

Страница 3: ...put features a parallel output and 0 dB 20 dB sensitivity switch Output modes include 4 constant impedance and 25V 50V 70V and 100V constant voltage The smart output stage is fully protected against p...

Страница 4: ...p supply if there s an AC power loss When both AC power and 24 VDC power are connected the DC power is switched off Note The unit is not equipped with battery charging capability The D C FUSE protects...

Страница 5: ...e Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace only with same type fuse The VOLTAGE SE...

Страница 6: ...TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SH...

Страница 7: ...ors are screw terminals Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers Strip the wire back about 1 2 inch loosen the screw enough to loop the wire around the shaft of the...

Страница 8: ...amplifier to allow adequate cooling for the heatsink Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation If the amplifier sho...

Страница 9: ...Series is shipped with the Standby Mode disabled Move jumper J1 on the input board to enable the Standby Mode see instructions on page 8 OVERL Connect an LED or relay between this terminal and the GND...

Страница 10: ...ts peak 10ms Frequency Response 50Hz to 15kHz 3 dB Distortion THD 1 1kHz nominal power Signal To Noise Ratio 80 dB below nominal power Audio Inputs Balanced Line Input One active balanced barrier stri...

Страница 11: ...l packaging Original packaging helps to minimize the possibility of shipping damage 3 Include a legible note stating your name return shipping address no P O boxes daytime phone number Return Authoriz...

Страница 12: ...888 337 7404 FAX 425 487 4337 industrial mackie com UK 44 1268 571 212 FAX 44 1268 570 809 industrial rcf uk com ITALY 39 0522 354 111 FAX 39 0522 926 208 industrial rcf it FRANCE 33 3 8546 9160 FAX...