Step 1 

–   Make all desired power, audio out, configuration 

switch and I/O connections to the unit and power up. Unit will 
perform a self test and enter idle mode. 

Step 2 

–   Provide a momentary or maintained contact closure 

between the message input (Connector 1, terminals 2-9) and 
common (Connector 1, terminal 1). Message Number Display 
will show the message number during playback. 

Step 3 

–   Provide a momentary contact closure to the stop 

input (Connector 1, terminal 10) to stop playback and return to 
idle mode, or allow message to play to end and the system will 
return to idle mode. 

 
The MacFi-se will ignore an input which corresponds to an 
empty or corrupt message location.  The Play relay contact will 
be maintained for the duration of play sequence. When playing 
multiple messages through queued messages or via maintained 
start activation’s, the system will drop the play relay for 
approximately 100mS between sequences. 

3.5 Memory Clear/Test 

Use this procedure when you wish to clear system memory of 
previously recorded messages or format the internal SD Card 

 

Step 1 

– Remove power from MacFi-se 

Step 2 

– Depress and hold Record Setup button while restoring 

power to MacFi-se. Continue to hold Record Setup button until 
Record Indicator remains ON, at which time it may be 
released. Record Indicator will remain ON and Status Display 
will read FC while system runs audio memory check. This 
process could take several minutes. 

Step 3 

– Wait until Record Indicator turns off, indicating memory 

check is complete and unit will perform as usual.  -or-  
Remove and reapply power to bypass memory test. 

3.6 Erase Message 

Individual message locations may be erased by simply recording 
a short (<1 second) message to that location. This short 
recording will instruct the system to erase the data from that 
message location. 

 

Remote Activation I/O: 

Control Inputs:  

Record, Stop, Sync, 8 individual message 
Start contacts. 

ICM-25(Option):  

Add to the MacFi-se for 25 more start inputs 
per module. 

Status Outputs:  

Playing, Sync 

Output Type:  

Dry relay contact, 1A @ 24VDC non-
inductive load 

Connection:  

Pluggable terminal 

 

Mechanical: 

Package: 

3 Way wall mount chassis,  
10" W x 8" D x 1.5" H 

Material: 

18 gauge cold rolled steel chassis; black 
painted finish, white silkscreen 

Rack mount(option):  1U adapter  
 

Regulatory Agency Approvals: 

FCC, Part 15, Class A; UL/CSA approval on external power  
pack(sold separately) 

 

Serial Interface: 

Type:  

RS-232 

Mode:  

9,600 or 115,200 baud, 8 data bits, 1 stop 
bit, no parity, no flow control  

Commands:  

Play, Record, Stop, File Download, Status, 
etc. (See Table 4.1) 

Connection:  

3 pin pluggable terminal 

 

Sync Input: 

Interface:  

10k ohm, RCA 

Mode:  

Audio sensor detects tones 100mS in 
duration

 

 

  

 

22 

 

Содержание MacFi-se

Страница 1: ...andwidth and memory configurations are available Page Stacker Feedback Eliminator Mackenzie s OPM series of Digital Page Stacker Repeater and Feedback Eliminators offer advanced features for the most...

Страница 2: ...nnected from both power and the rest of the phone system 11 Use Caution when installing or modifying configuration switches or control lines 12 The unit must be securely attached to a wall board rack...

Страница 3: ..._______________________________________________________________ __________________________________________________________________ Table of Contents 1 OVERVIEW 5 1 1 Features and Capabilities 5 Genera...

Страница 4: ...e proof of the date of original purchase In the event you need to ship your MacFi se system to the factory for service call us for a return authorization number When you ship your MacFi se system you...

Страница 5: ...007 FAX No 909 394 9411 1 OVERVIEW 1 1 Features and Capabilities The Mackenzie MacFi se family is the most cost effective series of MP3 Digital Audio Record Play Systems available for industrial usage...

Страница 6: ...ushbuttons Record Start Stop Select Sync LED s Display Overdrive Audio Sense Record Status Sync LED s message number display 4 MacFi se SERIAL PORT CONTROL The MacFi se includes an RS 232 Serial contr...

Страница 7: ...tor remains ON at which time it may be released Record Indicator will remain ON and Status Display will read FC while system runs audio memory check This process could take several minutes Step 3 Wait...

Страница 8: ...system OK 3 3 Playing Local Local playback is achieved through the LED s and buttons located on the front side of the MacFi se unit Please reference the Manual Button LED Configuration section of this...

Страница 9: ...e mode Step 2 Provide a maintained input signal between the Record Input and common this will blink the Record LED Step 3 Provide a maintained input signal between the message activation input desired...

Страница 10: ...for subsequent message activations Other play activations will be serviced normally even with another input held active indefinitely This mode supports message queuing Message queuing allows the user...

Страница 11: ...nce the queue is filled will be ignored A stop command will stop the message which is currently playing and when released the next message in queue will begin playing If multiple inputs are held activ...

Страница 12: ...lay Relay Output Normally Open 2 3 2 Audio Sense Indicator This green LED monitors the presence of audio on recording input This is designed to indicate that the audio level is optimum for system perf...

Страница 13: ...This red LED monitors the level of the recording input Overdriving the system will cause audio to clip adversely effecting sound quality Monitor the input material and set the input level just below o...

Страница 14: ...14 15...

Отзывы: