214658
45
Revision A
4.3.3
Installing Auger Fingers
The total number of fingers installed on the auger should be 22. Follow these steps to install the extra auger fingers
required to configure the header:
1.
Retrieve the bag of hardware from the manual storage case located on the back of the header.
1025996
A
D
C
B
E
Figure 4.34: Plastic Guides
2.
Remove screws (A) securing plastic plug (B) to the
auger and remove plug from inside the auger.
3.
Retrieve four plastic guides (C) from the bag of
hardware.
4.
Position plastic guide (C) in the hole from inside the
auger and secure with hex socket screws (D) and tee
nuts (E) provided in the hardware bag.
5.
Torque the screws to 8.5 Nm (75 lbf
∙
in).
6.
Repeat Steps
to
for the
remaining locations.
1007524
A
B
C
D
Figure 4.35: Auger Fingers
7.
Insert finger (A) through plastic guide (B) from inside
the auger.
8.
Insert finger into bushing (C).
9.
Secure finger (A) in bushing with hairpin (D). Install the
hairpin with its closed end positioned to lead in the
direction of the auger
’
s forward rotation.
10. Repeat Steps
to
for the
remaining fingers. There should be a total of 22 fingers
installed.
IMPORTANT:
To avoid damage to auger, check that all loose
hardware and tools are removed from inside the auger.
Содержание PW8