214658
120
Revision A
Calibrating Maximum Stubble Height
This procedure describes how to calibrate the area counter to stop or start counting at the correct height. Program
header to a height that will never be reached while cutting. The area counter will stop counting when header is
above programmed height, and will begin counting when header is below programmed height.
Select height of header that corresponds to description above.
IMPORTANT:
•
If value is set too low, area may
NOT
be counted since header is sometimes raised above this threshold
although combine is still cutting.
•
If value is set too high, area counter will keep counting even when header is raised (but below this threshold)
and combine is no longer cutting crop.
CAUTION
Check to be sure all bystanders have cleared the area.
1003774
Figure 6.94: New Holland Calibration
Dialog Box
1.
Select MAXIMUM STUBBLE HEIGHT calibration dialog
box. As you proceed through calibration process,
display will automatically update to show next step.
1003775
Figure 6.95: New Holland Calibration
Dialog Box
2.
Move header to correct position using header up or
down control switch on multifunction handle.
3.
Press ENTER to continue. As you proceed through
calibration process, display will automatically update to
show next step.
4.
Press ENTER or ESC to close calibration page. The
calibration is now complete.