214657
157
Revision A
Figure 4.129: New Holland Combine Display
6.
Select GRAPH (A). The exact voltage (B) is displayed
at top of page.
7.
Raise and lower header to see full range of voltage
readings.
8.
If sensor voltage is not within low and high limits shown
in
4.1.3 Height Sensor Output Voltage Range
Combine Requirements, page 102
, or if range between
low and high limits is insufficient, you need to make
adjustments. For instructions, refer to
Height Sensor Voltage Range (Left Side), page 105
and
Adjusting Header Height Sensor Voltage Range (Right
Side), page 105
Calibrating Auto Header Height Control (New Holland CR Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
Check following conditions before starting header calibration procedure:
•
The header is attached to combine.
•
The combine is on level ground, with header level to ground.
•
The engine is running.
•
The combine is not moving.
•
No faults have been received from Header Height Controller (HHC) module.
•
Header/feeder is disengaged.
•
Lateral float buttons are
NOT
pressed.
•
ESC key is
NOT
pressed.
To calibrate AHHC, follow these steps:
Содержание PW8
Страница 2: ...PW8 Pick Up Header Published May 2018...
Страница 3: ...Declaration of Conformity Figure 1 EC Declaration of Conformity 214657 i Revision A...
Страница 4: ...Figure 2 EC Declaration of Conformity 214657 ii Revision A...
Страница 40: ......
Страница 145: ...214657 131 Revision A Figure 4 73 John Deere Combine Control Console A Scroll Knob B Check Mark Button AHHC SYSTEM...
Страница 147: ...214657 133 Revision A AHHC SYSTEM...
Страница 176: ......
Страница 276: ......
Страница 282: ......
Страница 286: ......