214657
104
Revision A
Figure 4.19: Right Access Panel
7.
Remove two bolts (A) from access panel (B).
8.
Remove access panel (B).
Figure 4.20: Right Height Sensor
9.
Locate right height sensor (A).
NOTE:
Sensor may not be exactly as shown, and view of
harness is from inboard side of endsheet.
10. With connector plugged into the sensor, measure
voltage between the orange signal wire (B) in middle
position on connector, and the brown ground wire (C)
on one side of connector. This is maximum voltage for
the right sensor.
11. Start combine and fully lower combine feeder house.
The float springs should be fully compressed. Shut
down combine, and position the key so that power is
supplied to sensors.
12. Repeat voltage measurements for both sensors. These
are the minimum voltages.
13. Compare voltage measurements to specified values. Refer to
4.1.3 Height Sensor Output Voltage Range
Combine Requirements, page 102
.
14. If sensor voltage is outside low and high limits, or if voltage range is less than specified value, adjustments are
required. For instructions, refer to
Adjusting Header Height Sensor Voltage Range (Left Side), page 105
or
Adjusting Header Height Sensor Voltage Range (Right Side), page 105
Содержание PW8
Страница 2: ...PW8 Pick Up Header Published May 2018...
Страница 3: ...Declaration of Conformity Figure 1 EC Declaration of Conformity 214657 i Revision A...
Страница 4: ...Figure 2 EC Declaration of Conformity 214657 ii Revision A...
Страница 40: ......
Страница 145: ...214657 131 Revision A Figure 4 73 John Deere Combine Control Console A Scroll Knob B Check Mark Button AHHC SYSTEM...
Страница 147: ...214657 133 Revision A AHHC SYSTEM...
Страница 176: ......
Страница 276: ......
Страница 282: ......
Страница 286: ......