214657
124
Revision A
Figure 4.64: John Deere Combine Display
4.
Press UP or DOWN buttons until HDR appears on
monitor.
5.
Press ENTER button. HDR H-DN appears on monitor.
6.
Fully lower feeder house to ground.
NOTE:
You may need to hold HEADER DOWN switch for a few
seconds to ensure feeder house is fully lowered.
Figure 4.65: John Deere Combine Display
7.
Press CAL button (A) to save calibration of header.
HDR H-UP appears on monitor.
8.
Raise header 3 feet off the ground, and press CAL (A)
button. EOC appears on monitor.
9.
Press ENTER button (B) to save calibration of header.
Your AHHC is now calibrated.
NOTE:
If an error code appears during calibration, sensor is out
of voltage range and will require adjustment. Refer to
Calibrating Auto Header Height Control (John Deere 60
Series), page 123
.
NOTE:
After calibration is complete, adjust combine operation
settings to ensure proper field operation.
Содержание PW8
Страница 2: ...PW8 Pick Up Header Published May 2018...
Страница 3: ...Declaration of Conformity Figure 1 EC Declaration of Conformity 214657 i Revision A...
Страница 4: ...Figure 2 EC Declaration of Conformity 214657 ii Revision A...
Страница 40: ......
Страница 145: ...214657 131 Revision A Figure 4 73 John Deere Combine Control Console A Scroll Knob B Check Mark Button AHHC SYSTEM...
Страница 147: ...214657 133 Revision A AHHC SYSTEM...
Страница 176: ......
Страница 276: ......
Страница 282: ......
Страница 286: ......