20
installation of the unit into the housing
1. Slide the unit into the housing until it is firmly against the rear of
the housing. Care is required to ensure the foam sealing strips on
the housing remain in position.
2. Connect the air conditioner to the power and position excess cord
length beneath the air conditioner base.
3. Engage the chassis fixing brackets into the bottom housing rail
and secure to the base with the screw provided.
4. Remove the front panel from it's carton and plastic bag and fit as
per the Installation instruction.
5. Switch unit on. Check for operation of the unit and check for vi-
bration in the installation.
6. Fit the drain pan to the housing and run a drain line to a suitable
location if required.
Flash or seal around external
wall frame or architrave.
Ensure louver
is entirely
outside the wall
Drain pan
Steady bracket
(one per side).
Solid timber support
Sturdy timber
frame
Timber framed
wall or partition
Alternative installation method if
external support cannot be provided.
installation of the unit into the wall
Air IN
Air IN
Air OUT
Air IN
100 mm minimum
OPTION A
45° Brick cut away
to clear louver
45° Brick cut away
to clear louver
Front
Brick
wall
Brick
wall
100 mm
TOP VIEW
Air IN
Louver
Air OUT
100 mm
Air IN
OPTION B