17
2. Back drainage. Connect drain hose to the back drainage hole. It
will slightly affect cooling performance, but will reduce the noise
caused by spraying the condensed water.
3. Non-drainage. Block the drain hole(s) by rubber plug(s).
The condensed water will be sprayed to condenser, and will im-
prove the cooling performance.
Installation procedure of bottom drainage:
1. Remove the rubber plug from the bottom of cabinet (if installed).
2. Take out the drain tray and screws from accessory.
3. Fix the drain tray onto the bottom of cabinet by screws.
4. Connect an extension drain hose (locally purchased) to the outlet
of drain tray.
Bottom drain hole
Rubber plug
Rubber
plug
Screw
Drain pan
Drain
outlet
Installation procedure of back drainage:
1. Fit the seal (provided as accessory) onto the drain joint.
2. Insert the drain joint to the back drainage hole, and rotate it 90°
to be well fitted.
3. Connect an extension drain hose (locally purchased) to the drain
joint.
4. Make sure to block the bottom drain hole by rubble plug.
Note:
Drain hose is locally purchased according to installation
length request.
Rubber
plug
Seal
Drain
joint
Back drain
hole