Note:
If you choose non-drainage when cooling, both the bottom
and the back drain holes of the unit should be inserted with rubber
plugs. When you choose non-drainage the air conditioner will be
perfect cooling efficiency, but big noise may be caused by spraying
the condensed water. Does not recommend to use.
Note:
The rated cooling performance is tested under non-drainage
status.
Note:
Make sure that water will not leak from the surrounding area
when rubber plug and joint were used. Please seal it in case leakage
is found.
installation instructions
Note:
Before installing, remove all packaging from inside the car-
ton, along with any inserts placed into the side louvers.
select the best location
1. To avoid vibration and noise, make sure the unit is installed se-
curely and firmly.
2. Install the unit where the sunlight does not shine directly on the
unit. If the unit receives direct sunlight, build an awning to shade
the cabinet.
3. There should be no obstacle, such as a fence or wall, within 50 cm
from the back of the cabinet because it will prevent heat radia-
tion of the condenser.
Restriction of outside air will greatly reduce the cooling and heat-
ing efficiency of the air conditioner.
4. Install the unit a little obliquely downward to outside not to leak
the condensed water into the room (about 3~40 with level).
5. Install the unit with its bottom portion 75~150cm above the floor
level.
6. The power cord must be connected to an independent circuit. The
yellow/green wire must be grounded.
Awning
Fence
Level
Unit
About 3~4°
Over 50 cm
75~150
cm
Awning
Fence
Level
Unit
About 3~4°
Over 50 cm
75~150
cm