background image

13

Dry

This mode is used to decrease the humidity in the room. Under this
mode, you cannot select a fan speed. The fan motor operates at
LOW speed. Keep windows and doors closed for the best dehumidi-
fying effect.

Cool

Temperature setting is adjustable between 16 °C to 31 °C. You can
select a desired fan speed.

AUTO (on some models)

The fan motor remains on MED speed during AUTO mode. The unit
will select the appropriate operating mode from FAN, COOL or HEAT
(on reverse cycle models only) based upon the temperature differ-
ence between the actual and the desired room temperature. On
models not equipped with the MED speed, the fan motor operates
on HIGH speed in AUTO mode.

Sleep (on some models)

Press and hold the SWING keypad for 2 seconds or use the remote
control to activate or deactivate the SLEEP feature. When the sleep
feature is activated, the indicator light next to SLEEP will illuminate.

In the Cooling mode, the cooling temperature set point will increase
1°C per hour after the SLEEP mode is selected. Two hours later, the
set point will continue at this temperature and the fan motor will
remain on LOW speed.

Using the SLEEP mode will reduce noise, creating a comfortable
sleeping environment.

LED display

Shows the temperature setting or the Auto-Timer setting. After 10
seconds, it shows the room temperature (on some models) or the set
temperature (on some models).

Error codes (on some models)

Eo:

 Indicates a malfunction of the outdoor condenser temperature

sensor.

When one of the above malfunctions occurs, turn off the unit, and
check for any obstructions. Restart the unit, if the malfunction is still
present, turn off the unit and unplug the power cord. Contact the
manufacturer or its service agents.

En:

 Indicates a malfunction of the evaporator temperature sensor.

Er:

 Indicates a malfunction of the indoor room temperature sensor.

TIMER OFF for cooling and fan operation

• On cool mode, press the TIMER button for 2 seconds, the TIMER

OFF light illuminates and the cool mode light flashes. This indicates
that the Auto Stop program for cooling operation is initiated.
Press the MODE button, the fan mode light flashes, it indicates
that the Auto Stop program for fan operation is initiated. Press the
UP or DOWN button to select the desired time.

• On fan mode, press the TIMER button for 2 seconds, the TIMER

OFF light illuminates and the fan mode light flashes. This indicates
the Auto Stop program for fan operation is initiated. Press the UP
or DOWN button to select the desired time.

• Press or hold the UP or DOWN button to change the Auto Stop

time by 0.5 hour increments, up to 10 hours, then at 1 hour incre-
ments up to 24 hours. The control will count down the time re-
maining until stop.

• Adjusting the timer setting to 0.0 will cancel the Auto Stop timer

program.

Содержание MEE09VV

Страница 1: ...1 owner s manual window type air conditioner model MEE09VV read this manual before installing your new air conditioner PM01...

Страница 2: ...2...

Страница 3: ...is product as unsorted munici pal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal th...

Страница 4: ...void a hazard Do not modify power cord length or share the outlet with other appliances It may cause electric shock or fire due to heat generation Do not operate the unit with wet hands or in damp env...

Страница 5: ...it to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation and close the window before a storm or hurri cane Operation with windows open...

Страница 6: ...rotection The specifications of the fuse are printed on the circuit board such as T 3 15 A 250 V etc Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do n...

Страница 7: ...use water to clean the interior of the air conditioner Expo sure to water can destroy the insulation leading to possible elec tric shock When cleaning and maintenance the unit first make sure that th...

Страница 8: ...ly grounded The wall outlet air break switch should be provided with a reliable ground wire The unit should be provided with an individual circuit and the cir cuit breaker fuse rating should be the sa...

Страница 9: ...me The follow ing illustration is for explanation purpose only the actual shape of the machine you purchased may be slightly different 8 7 6 3 2 1 1 2 3 3 5 6 7 8 9 Model A Front panel Air filter Fram...

Страница 10: ...model you purchased All the illustrations in the manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail Seal optional Used on drain join...

Страница 11: ...pull the lever toward you To close the vent push it in To open the vent set the lever to the right position To close it set the lever to the left position operation instructions control panel LOW MOD...

Страница 12: ...wing feature The indicator light next to the SWING keypad will illuminate identi fying the selected mode The vertical louvers will oscillate back and forth side to side automatically sweeping air alte...

Страница 13: ...onds it shows the room temperature on some models or the set temperature on some models Error codes on some models Eo Indicates a malfunction of the outdoor condenser temperature sensor When one of th...

Страница 14: ...you will require two AAA 1 5 Volt batteries included Batteries should be replaced when No signal beep is heard from the main unit when initiating pro gram commands from the remote control The main uni...

Страница 15: ...select either COOLING FAN or DRY mode Set AUTO temperature on some models Press the TEMP UP DOWN pads to select increase decrease the de sired operating temperature The selected temperature will appea...

Страница 16: ...e at the maximum upwards or downwards angle position for a long time in cooling or drying mode air filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 wee...

Страница 17: ...brush to clean the front panel as this will damage the surface of the part winter storage If you plan to store the air conditioner during the winter remove it carefully from the window according to th...

Страница 18: ...essories bag 3 Fix the drain tray onto the bottom of cabinet using the screws 4 Connect an extension drain hose locally purchased to the outlet of drain tray Bottom drain hole Rubber plug Rubber plug...

Страница 19: ...d vibration and noise make sure the unit is installed se curely and firmly 2 Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build an awnin...

Страница 20: ...lope down towards the rear by about 5 mm to allow wa ter generated during operation to drain Step 3 Install the housing into the wall and secure Make sure the foam seals are not damaged Flash seal or...

Страница 21: ...on instruction 5 Switch unit on Check for operation of the unit and check for vi bration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required...

Страница 22: ...er there are four kinds of removing the frame Remove the two screws on the left and right chassis fixing brackets Then remove the two chassis fixing brackets as shown in Fig 3A Remove one screw on the...

Страница 23: ...he cabinet See Fig 6 3 Push the unit chassis into the cabinet See Fig 7 Fig 9 Fig 8 Step 4 Install the frame 1 Install the frame and connect the coupler plugs making sure not to interfere with the tem...

Страница 24: ...rainy days The water may overflow and drip from the outdoor side of the unit The fan may continue to operate when the compressor has cycled off What to do The air conditioner is unplugged Air conditio...

Страница 25: ...tions section Ambient temperature is high When the air condi tioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and...

Страница 26: ...h Model Note D value is for reference only Minimum nominal cross section area of conductors Rated current of appliance A Nominal cross section area 3 y 6 6 y 10 10 y 16 16 y 25 0 75 mm 1 mm 1 5 mm 2 5...

Страница 27: ...27...

Страница 28: ...28...

Отзывы: