8
operating temperature
Note:
Performance may be reduced outside of these operating tem-
peratures.
Cooling operation
Outdoor
temperature
Indoor
temperature
18-43°C/64-109°F (18-52°C/64-
125°F for special tropical models).
17-32°C/62-90°F
power point requirement
• Power cord conductors are distinguished according to color as fol-
lows (see Fig. A).
• For your safety and protection, this unit is grounded through the
power cord (see Fig. B). Contact the manufacturer or the autho-
rized service center to have it replaced.
• Make sure the unit has being correctly grounded. The wall outlet
(air-break switch) should be provided with a reliable ground wire.
• The unit should be provided with an individual circuit and the cir-
cuit breaker/fuse rating should be the same as that of the power
cord and wall outlet.
Power cord
L
G
N
G - Ground wire, Yellow/Green
N - Neutral wire, Blue
L - Live wire, Brown
Fig. A
Wall outlet
Air-break switch
Fig. B
Auto-Restart (on some models)
If the unit breaks off unexpectedly due to a power cut, it will restart
with the previous function setting automatically when the power re-
sumes.
Wait 3 minutes before resumig operation.
After the unit has stopped, operation cannot be restarted in the first
3 minutes. This is to protect the unit. Operation will automatically
start after 3 minutes.