![M86 Security Threat Analysis Reporter Скачать руководство пользователя страница 181](http://html1.mh-extra.com/html/m86-security/threat-analysis-reporter/threat-analysis-reporter_user-manual_3144283181.webp)
A
PPENDICES
S
ECTION
A
PPENDIX
C
M86 S
ECURITY
U
SER
G
UIDE
171
Step 5: Contact Technical Support
Contact Technical Support to order a new replacement hard
drive and for instructions on returning your failed hard drive
to M86 Security.
Power supply failure
Step 1: Identify the failed power supply
The administrator of the server is alerted to a power supply
failure on the chassis by an audible alarm and an amber
power supply LED—or an unlit LED—on the front and rear
of the chassis.
NOTE
: A steady amber power supply LED also may indicate a
disconnected or loose power supply cord. Verify that the power
supply cord is plugged in completely before removing a power
supply.
WARNING
: Be sure the correct failed power supply has been
identified. Removing the wrong power supply will cause the
system to crash.
Step 2: Unplug the power cord
To prevent electrical shock to yourself and damage to the
unit, unplug the power cord from the failed power supply.