Antenna 

The standard antenna provided with the control panel, must be mounted inside the panel. 

The antenna is supplied with SMA connector, that allows easy connection to the panel. The antenna 
should be position perpendicular to the ground. Try to keep the antenna away from sources of RF 
interference or where metal objects can shield it or otherwise block the cellular radio RF signal. 

WARNING

: The internal antenna used with this product must be installed to provide separation distance 

of at least 7.8 in (20cm) from all persons and must not be co-located or operating in conjunction with any 
other antenna or transmitter except in accordance with FCC multi-transmitter product procedure. 

 

NOTE:

 Antenna problems are rare unless the premises are in an area with poor network coverage, in a 

building below ground, or in a metal structure.  

Do not use the unit with a damaged antenna. Have your antenna replaced immediately. Use only a 
manufacturer approved antenna. Non-approved antennas or modifications could impair service quality, 
damage the device and violate FCC regulations. 

 

Keypad 

Mount the keypad where it is accessible, in a dry and secure location. Perform the following steps to 
mount the keypad: 

  Remove the keypad front plate by inserting a screwdriver into the slots located on the top of the 

keypad. 

  Remove the keypad backplate by inserting a screwdriver into the slots located near the bottom of 

the back plate and prying up to remove the backplate. 

  Secure the keypad backplate to the wall in the desired location. Lift the keypad door. Use all 

screw provided. Use the plastic anchors supplied if the unit is to be mounted on drywall. 

  To use the keypad tamper, insert the supplied tamper to the wall with a screw. 

  For tamper use, the backplate should be mounted on a smooth, flat surface. If mounting is on 

rough surface, fasten the enclosed surface tape to the wall to eve out the surface area where the 
tamper will be positioned. 

  Before attaching the keypad to its backplate, complete the keypad wiring as described in the next 

section. 

Backup Battery 

In the event of an AC power loss, the system is supplied with backup battery that is supervised for 
connection and low voltage conditions. This information is available to the monitoring station and the 
M2M platform. 

NOTE:

 On a typical installation the battery will last for at least 24 hours. 

 

 

Содержание RControl-LA

Страница 1: ...M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria www m2mservices com RControl LA Smart Hybrid Alarm System Installation and Programming Guide Doc No 04003 V1 0 10 2018...

Страница 2: ...keyfobs 11 Labelling the keyfobs 11 Con guring the panic button of the keyfob 11 Wireless detectors 12 Pairing a wireless detector 12 Disabling a wireless detector 13 Deleting a wireless detector 13...

Страница 3: ...o its intended purpose and does not cover damage to the Device caused by installation or removal of the Device or any of its components This warranty is voided if the Device has been damaged by improp...

Страница 4: ...ust be done only by qualified safety aware personnel Don t disassemble or refit the Device Do not attempt to personally repair it Main powers must be disconnected before any installation or tuning wor...

Страница 5: ...artition control panel with the following features Built in GPRS communicator Remote control via Smartphone 2 Partitions 8 Wired zones 16 with zone doubling 32 Wireless zones Supports up to 16 keyfobs...

Страница 6: ...output 200 mA Power Requirements Battery 12 V 2 6 Ah minimum rechargeable sealed lead battery Digital Communicator Specification Built in digital communicator Frequency Dual band UMTS HSPA 850 1900 MH...

Страница 7: ...choose location that is below ground level as this can impair wireless reception Do not choose location that can be easily viewed from outside the premises The Control Panel should be mounted on the w...

Страница 8: ...te FCC regulations Keypad Mount the keypad where it is accessible in a dry and secure location Perform the following steps to mount the keypad Remove the keypad front plate by inserting a screwdriver...

Страница 9: ...the alarm panel Battery Plug the battery connector into the connector on the control panel s circuit board Plug the red cable to the of the battery and the blue one to the of the battery Ensure the ba...

Страница 10: ...take which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 30 seconds If the receiver does not receive signal from the keyfob in the timeframe of 30 sec...

Страница 11: ...e for each keyfob Labelling the keyfobs Each keyfob reports with different user number in the range between 101 116 When pairing the keyfobs they automatically receive labels Keyfob 101 Keyfob 116 The...

Страница 12: ...beep once and the red PAIR LED will turn off The siren will beep four times if there was an error during the pairing When a new detector is successfully paired the panel reports an event Module Added...

Страница 13: ...all keyfobs and wireless detectors NOTE This procedure will delete all paired keyfobs and wireless detectors To pair the keyfobs and the wireless detectors again you should repeat the pairing procedu...

Страница 14: ...tor as many times as required until the panel recognizes the sensor When the sensor is successfully enrolled the panel will beep once and the red PAIR LED will turn off The siren will beep four times...

Страница 15: ...wer you can configure the delay in seconds after which the device will report the mains power outage Configuring the Battery level thresholds In section Battery field Battery low you can set a low vol...

Страница 16: ...en the alarm cycle time expires the zone restore event will be reported only when the zone is really restored In addition even when there was a restore during the alarm cycle this restore will not be...

Страница 17: ...h prevent the panel from arming Follow STAY zone This is a Follow zone that is not monitored when the panel is partially armed STAY Arm Instant STAY zone This is an Instant zone that is not monitored...

Страница 18: ...pressed 24 Hours Flood When this zone is violated the panel will immediately latch the alarm output and communicate to the central station The alarm will sound until the alarm cycle duration expires o...

Страница 19: ...is strongly recommended that the end user changes the User name and Password and provides an email for password recovery Remote Arming Disarming via the RControl Application To enable the remote contr...

Страница 20: ...exit the System Test mode and indicate this with a sound The programming icon will also be off If some of the sensors is not activated the system will not generate a sound indication for exiting a te...

Страница 21: ...8 1 0 2 s e c i v r e S M 2 M 1 2 Zone problems Wiring Configuration Faulty detectors Siren not working Check wiring Programming AUX overcurrent...

Отзывы: