Entry/Exit zone
– The Entry/Exit zones can be violated during the entry/exit time delay without
causing an alarm event.
If an Entry/Exit zone is violated while the system is armed, the alarm panel will start counting the
entry time. If the system is not disarmed during the entry time, an alarm event is generated.
NOTE:
If the entry/exit time is 0 sec, the Entry/Exit zone works as an Instant zone.
The exit time should not be more than 120 secs.
The entry time should not be more than 45 seconds.
•
Follow zone -
This zone can be violated during the entry/exit delay time without generating an alarm
event. If the zone is violated while the panel is armed, the panel immediately generates an alarm
event (without counting entry time). It is called “Follow” zone because it depends on the Entry/Exit
zone. If the Follow zone is violated after an Entry/Exit zone has also been violated, then the alarm
panel will wait until the entry time passes before generating an alarm event.
If the Follow zone was violated before any Entry/Exit zone was violated, then an alarm event will be
generated immediately.
•
Instant zone
- If this type of zone has been violated when the panel is armed, the panel will
immediately generate an alarm event. The arming of the alarm panel is not being possible if an
Instant zone is violated. In this case the alarm panel sends a Contact ID event E-374
(Exit Error, in
Zone N), reporting first the violated zones which prevent the panel from arming.
•
Follow STAY zone -
This is a Follow zone that is not monitored when the panel is partially armed
(STAY Arm)
•
Instant STAY zone -
This is an Instant zone that is not monitored when the panel is partially armed
(STAY Arm)
•
24 Hours Tamper
– If this zone is violated, the valid user’s code must be entered before the system
can be armed. This can be accomplished also by pressing the disarm button of the keyfob.
•
24 Hours Fire
– When this zone is violated, the panel will immediately latch the alarm output and
communicate to the central station. The siren will follow the fire pattern, the fire icon and zone number
will be lit. The alarm will sound until the alarm cycle duration expires, or until a code is entered or the
disarm button of the keyfob is pressed.
•
24 Hours Alarm
– When this zone is violated, the panel will immediately latch the alarm output and
communicate to the central station. The alarm will sound until the alarm cycle duration expires, or
until a code is entered or the disarm button of the keyfob is pressed.
•
24 Hours Panic
– This zone is silent. When the zone is violated, an event will be send to the central
station and the zone number will be lit. The restore will come after the zone is closed.
•
24 Hours Medical
– When this zone is violated, the panel will immediately latch the alarm output and
communicate to the central station. The siren will follow the alarm pattern and zone number will be lit.
•
24 Hours Sprinkler
– When this zone is violated, the panel will immediately latch the alarm output
and communicate to the central station. The siren will follow the trouble pattern, the fire icon and zone
number will be lit.