Appendix C – Installing the SD-Card 

To insert a card into the reader orientate it as showed below, and push the card into the 
reader until a click sound occurs. Remove the card by pushing it into the reader until it 
clicks and the reader will eject the card. Avoid removing the SD-CARD during access to 
the card. 
 

 

SD-Card orientation 

 
 
 

 

 

 

 

 

 
 

Содержание C350 pro

Страница 1: ...Technical Manual 1 02 C350 Professional Technical Manual for the C350 pro Version 1 02...

Страница 2: ...r SCADA like applications The C350 pro offers many other sophisticated features such as A 512kbyte internal flash drive and a SD CARD reader with a FAT32 compatible file system for easy sharing of fil...

Страница 3: ...nalog outputs 15 RS232 communication ports EIA TIA 232 and V 28 V 24 compatible 16 Serial port 1 programming port 16 Serial port 2 17 RS485 communication ports EIA TIA 485 A compatible 18 RS485 port s...

Страница 4: ...y Infranet Technologies GmbH Ph 49 40 69647 260 Tempowerkring 2 Fax 49 40 69647 259 21079 Hamburg Email info m2mcontrol de Germany Web www m2mcontrol de Technical Manual 1 02 C350 Professional Page 4...

Страница 5: ...re available externally for easy access this also includes SIM Card and SD Card On the front a human user interface is found this includes a 144x32 easy to read graphical LCD for showing information t...

Страница 6: ...ble screw terminals or standardized connectors Also available are SIM card reader with lock 3 3VDC output for driving external accessories and equipment and all the analog inputs and outputs Bottom si...

Страница 7: ...normally unconnected if programming cable connect to SGND 3 DC OUT 3 3V 400mA DC OUT for external equipment 4 RXD Receive data for serial port 1 RS232 compatible 5 SGND Signal ground 6 SGND Signal gr...

Страница 8: ...ire LED 1 Wire ID Button LED 9 SGND Signal ground 10 RS485_1 RS485 non inverting signal for standard RS485 port 11 RS485_1 RS485 inverting signal for standard RS485 port 12 SGND Signal ground 13 RS485...

Страница 9: ...put 3 43 DIN4 S0IN4 Digital input 4 S0 input 4 44 DIN5 WAKEUP Digital input 5 Wakeup ignition input 45 DIN6 Digital input 6 46 DIN7 Digital input 7 47 DIN8 Digital input 8 48 SGND Signal ground 49 SGN...

Страница 10: ...d is used as a low noise analog ground reference for the analog inputs The C350 pro is protected against wrong polarity If a chassis or system grounds are connected to either SGND or AGND a wrong pola...

Страница 11: ...The digital outputs are supplied directly from the SUPP power pins which also supplies the rest of the C350 unit As the power is also the C350 pro main power a power fail would also affect the digital...

Страница 12: ...62053 31 Class B and DIN5 can work as wakeup ignition input As default the digital inputs are configured as normal inputs For placement and configuration of the hardware jumpers inside the unit please...

Страница 13: ...must be greater than 2 ms to be valid The power management allows the possibility to configure a wakeup on one or more digital inputs with individually configured falling or rising edge detection Plea...

Страница 14: ...nfigured as voltage inputs For placement and configuration of the hardware jumpers inside the unit please refer to the unit configuration guide in Appendix A The input signal is connected between AINx...

Страница 15: ...AGND AGND must be connected to the reference of the connected equipment Please be aware that deviations may occur as the system is very noise sensitive Avoid long unshielded wires and large fast chan...

Страница 16: ...erial port 1 programming port This port can be used as general purpose RS232 serial port or as a C350 pro programming port In order to use the port for programming the RS DET pin must be connected to...

Страница 17: ...350 pro unit Serial port 2 can also be allowed to hand over functionality to the internal GSM module to work as GSM modem Using this mode will effectively hand over the GSM module inside the C350 pro...

Страница 18: ...te it and avoid signal reflections If the C350 pro is use as endpoint unit the hardware jumper JP7 standard port JP12 optional port can be installed to terminate the RS485 communication lines with 120...

Страница 19: ...RS485 port is installed and enabled RS485 will be available on the pluggable screw terminals Internally this RS485 port and the programming port share the same signals and RS485 will be disabled if a...

Страница 20: ...gured with the correct network parameters it will lead to network corruption and may interfere with other connected equipment on the bus Especially in vehicles great precautions must be observed to pr...

Страница 21: ...ase consult the M2M Control IDE on line help for further information 1 Wire pins Pin Name Description 7 1Wire 1 Wire bus for ID Button Temperature sensor 8 1Wire LED 1 Wire ID Button LED 9 SGND Signal...

Страница 22: ...els white on blue graphical display A range of display functions is available to make graphical and alpha numerical presentation of the data user interaction with menus etc The display is fully backwa...

Страница 23: ...ery icon means low battery level While charging the battery battery icon is animated to show all the levels with 1 second delay Power state of the display is saved in persistent memory and the state w...

Страница 24: ...d in the table below If the color of the system LED 1 2 is yellow the unit is actively communicating with for example the M2M Control IDE program or another program supporting the RTCU protocol RACP S...

Страница 25: ...witches is located on the top side of the unit for easy user access see the graphical view To use the dipswitch in the M2M Control IDE declare a Boolean input variable and define it as a dipswitch in...

Страница 26: ...hnical specifications Make sure both power supply and cables can handle the high current The battery will be charged whenever a power fail has occurred to establish the capacity making the battery rea...

Страница 27: ...echanical lock for secure installation of the SIM card Please refer to Appendix B for SIM card installation guide It is possible to detect the state of both the SIM Insert and SIM lock status from the...

Страница 28: ...compatibility Up to 2 GByte capacity is supported The SD CARD features a push push eject system for reliable insertion and operation Please refer to Appendix C for SD Card installation guide Both the...

Страница 29: ...70 50 mA Unit active while charging 900 580 300 mA Unit in power down 0 8 0 6 0 3 mA Restart on DIN5 RTC Unit in wait for event 0 8 0 6 0 3 mA Resume on DIN RTC Unit in wait for event 17 12 4 mA Resu...

Страница 30: ...y Infranet Technologies GmbH Ph 49 40 69647 260 Tempowerkring 2 Fax 49 40 69647 259 21079 Hamburg Email info m2mcontrol de Germany Web www m2mcontrol de Technical Manual 1 02 C350 Professional Page 30...

Страница 31: ...nit configuration guide The C350 has many features and some of them requires configuration by setting hardware jumpers inside the unit The following figure shows the location of the jumpers when the l...

Страница 32: ...hm resistor enabled 120 ohm resistor disabled default JP1 Installed Not installed AIN1 current measurement AIN1 voltage measurement default JP14 Installed Not installed AIN2 current measurement AIN2 v...

Страница 33: ...resistor are disabled JP1 JP14 JP16 and JP17 These jumpers are used to select between current and voltage input With a jumper installed on the relevant analog input it will measure current between 0...

Страница 34: ...ntrol de Germany Web www m2mcontrol de Technical Manual 1 02 C350 Professional Page 34 of 38 Opening the lid 1 Place a screwdriver or a flat tipped tool as shown in the picture and lift the screwdrive...

Страница 35: ...9647 260 Tempowerkring 2 Fax 49 40 69647 259 21079 Hamburg Email info m2mcontrol de Germany Web www m2mcontrol de Technical Manual 1 02 C350 Professional Page 35 of 38 3 Rest the lid as in the followi...

Страница 36: ...2mcontrol de Technical Manual 1 02 C350 Professional Page 36 of 38 Closing the lid 1 Begin with placing the left side of the lid into the tap of the bottom part close the lid gently 2 Make sure that t...

Страница 37: ...to the card reader Push the card into the reader until a click sound occurs the card will now stay in its position It might be necessary to use a small tool or pencil as the card for protection purpos...

Страница 38: ...hnical Manual 1 02 C350 Professional Page 38 of 38 Appendix C Installing the SD Card To insert a card into the reader orientate it as showed below and push the card into the reader until a click sound...

Отзывы: