Chapter 8 Maintenance 

 
8.1 Surface Cleaning 

Use soft cloth wet by detergent to wipe dirty surface of case out. 

 

8.2 Regular Inspection 

For the best operational condition, the product needs regular inspection. 
 
(1) Environment 

a. Does the equipment operate within the allowable range of temperature(-10°C~50°C)? 
b. Does the equipment operate within the allowable range of humidity(10%~80%RH)? 
c. Is there no corrosive gas around?   

 
(2) Power   

a. Is the input voltage range? 

 

(3) Related Items 

a. Check the touch pad there is no damage, scratch or pollution. 

 

8.3 Problems with the Product 

 
(1) When a problem occurs during operation, stop using the product and contact the A/S department of M2I 
Corporation to report the problem(s) you faced. 
(2)  Only  an  authorized  worker  by  M2I  Corporation  can  check  and  repair  the  product  in  relation  to  the 
malfunctions of the product. 
(3)  In  case  that  the  problem  is  not  fixed  at  the  site  of  installation,  the  equipment  can  be  brought  to  M2I 
Corporation for repair. 
(4) The manufacturer, M2I Corporation, is not liable for any damage or malfunctions of the equipment caused 
by a user's arbitrary installation and use not described, specified, and/or recommended in this manual. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TOPRHWS

Страница 1: ...gan gu Anyang si Gyeonggi do 14055 Republic of Korea 1 19 Thank you for purchasing M2I TOPRHWS Please read this user manual carefully for safe installation wiring and operation of this equipment befor...

Страница 2: ...Serial Communication Specifications 7 5 2 Ethernet Communication Specifications 8 Chapter 6 Block Diagram for Installation 9 6 1 Connection Diagram 9 6 2 Panel Cut Size for Front Panel Installation 1...

Страница 3: ...store or operate in an environment exposed to sunlight Do not touch an adaptor or power code with wet hands It can cause electric shock Do not use this product in explosive environments with flammabl...

Страница 4: ...erminal screw with the specified torque The loose screws of the terminal can be the cause of short circuit a fire or and malfunction Use a standard earthing for FG terminal When not earthed it can cau...

Страница 5: ...she operates and monitors an installation system 2 2 Components The components of the product are as follows Before use please check that all of the following components are included Item Picture Quan...

Страница 6: ...Pulse width 1 Static Electricity Discharge Connective discharge from EN61000 4 2 4 Shock Endurance 10G X Y Z each direction for 3 times Surge Voltage 500V Line Line Ground Connection Class 3 100 under...

Страница 7: ...About 15m Type of connection 1 1 Control code ASCII Code or HEXA Code Baud rate 2400 4800 9600 19200 38400 57600 76800 115200 bps Data type Data Bit 7 8 bit Parity Bit NONE ODD EVEN Parity Stop Bit 1...

Страница 8: ...ations 5 2 1 Ethernet Item Specification Ethernet Method IEEE802 3i IEEE802 3u 10BaseT 100BaseT Speed 10M 100Mbps Communication Method Base Band Switching Method AUTO MDIX Maximum Segment Length 100m...

Страница 9: ...xposing the front and the other is fixing it to DIN Rail of the rear TOPRHWS is connected to TOPRH0700WD FE with predefined 26 fin cable 6 1 Connection Diagram TOPRHWS should be connected with the mai...

Страница 10: ...anel Cut Size for Front Panel Installation Please refer to below drawings for front panel installation TOPRHWS TOPRHWS02 6 3 Cable Diagram Please check part information of TOPRH0700WD FE connecting ca...

Страница 11: ...EMG A1_com PAIR5 14 COMM_8 EMG A1 contact PAIR5 15 EXT0_EMG_B1 EMG B1_com PAIR6 16 EXT0_EMG_A1 EMG B1 contact PAIR6 17 COMM_13 EMG B2_com PAIR7 18 COMM_12 EMG B2 contact PAIR7 19 3P_SW_A0_COM 3Positi...

Страница 12: ...6 A6 EMG A1 contact PAIR5 Emergency_A1 Out 7 A7 EMG B1_com PAIR6 Emergency_B1 com 8 A8 EMG B1 contact PAIR6 Emergency_B1 Out 9 B1 EMG B2_com PAIR7 Emergency_B2 com 10 B2 EMG B2 contact PAIR7 Emergency...

Страница 13: ...RH0700WD FE and TOPRHWS should be identical 1 It can be set for Serial or Ethernet communication 2 When using serial communication mode it is possible to use RS 232C 422 485 When Ethernet is selected...

Страница 14: ...s wired as follows Position EMG_A1 EMG_B1 EMG_B2 Not Pressed Open OFF Short ON Short ON Pressed Short ON Open OFF Open OFF It is a mechanical switch which can operate regardless on off status of main...

Страница 15: ...ditionally controls the controllability of the controller A source type function key cannot be used Signal Fn Dout 0 F1 Dout 1 F2 Dout 2 F3 Dout 3 F4 Dout 4 F5 Dout 5 F6 Dout_com It runs with a photoc...

Страница 16: ...troller Position 3P_SW_A0 3P_SW_A2 NOT Pressed Open OFF Open OFF HALF Pressed Short ON Short ON Fully Pressed Open OFF Open OFF It is a mechanical switch which can operate regardless on off status of...

Страница 17: ...When installing the power plug use a pin terminal to improve the coupling of power wire and electrical transmission Attach the power cable to the power terminal of the equipment as below 1 Below are t...

Страница 18: ...wer a Is the input voltage range 3 Related Items a Check the touch pad there is no damage scratch or pollution 8 3 Problems with the Product 1 When a problem occurs during operation stop using the pro...

Страница 19: ...Temperature 10 Ta 50 Power Specifications TOPRHWS 24Vdc 20W or less TOPRHWS02 24Vdc 20W or less KC Certificate No Product No Copyright M2I corporation 2022 08 www m2i co kr When using M2I equipment r...

Отзывы: