![M2I TOPRHWS Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/m2i/toprhws/toprhws_hardware-manual_3122235015.webp)
TOPRHWS Hardware Manual
M
2
I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055,Republic of Korea
15 / 19
(2) Keylock: wiring diagram
For safety, it additionally controls the controllability of the controller.
Position
Status
"A" direction
Open(OFF)
"B" direction
Short(ON)
(*It runs with a photocoupler, so it can be controlled only when the main body turns on.)
(3) Function key: wiring diagram
It additionally controls the controllability of the controller.
A source-type function key cannot be used.
Signal
Fn
Dout 0
F1
Dout 1
F2
Dout 2
F3
Dout 3
F4
Dout 4
F5
Dout 5
F6
Dout_com
-
(*It runs with a photocoupler, so it can be controlled only when the main body turns on.)
VC C
VC C
VC C
VC C
VC C
VC C
PLC DC
제 어
#1
PLC DC
제 어
#2
PLC DC
제 어
#3
PLC DC
제 어
#4
PLC DC
제 어
#5
PLC DC
제 어
#6
TOPRH Fn Switch
(Sink Type)
Dout_com
Dout_com
Dout_com
Dout_com
Dout_com
0
1
2
3
4
5
Dout0
Dout1
Dout2
Dout3
Dout4
Dout5
Dout_com
0
1
VC C
PLC DC
제 어
TOPRH KEY LOCK Switch
(Sink Type)
KEY LOCK
KEY LOCK_com
1
0
PLC DC
제 어
VC C
KEY LOCK
TOPRH KEY LOCK Switch
(Source Type)
KEY LOCK_com