6.4 Mechanical Switch Setting of TOPRH0700WD FE Main Body
6.4.1 Switch Layout
This product is designed to selectively use necessary operation by controlling S/W of TOPRH0700WD FE.
6.4.2 Allocating Operation to TOPRH0700WD FE S/W (SW12, SW13, SW14)
When using TOPRHWS, position all S/W to the right side.
6.5 Serial and Ethernet Communication Setting Switch
6.5.1 Communication Channel and I/F Setting
For SW11 switch, the settings of TOPRH0700WD FE and TOPRHWS should be identical.
(1)
It can be set for Serial or Ethernet communication.
(2)
When using serial communication mode, it is possible to use RS-232C/422/485. When Ethernet is selected
for communication, COM1 serial communication cannot be used.
(3)
The setting of serial communication can be changed at 'System Control Panel' -> 'Serial' menu’.
(4)
The setting of Ethernet communication can be changed at 'System Control Panel' -> ' Ethernet ' menu. IP of
PLC can be set and changed in the communication device PLC. For it, however, Ethernet PLC should be
included in the design.
6.6 The Purpose and examples of External Functions
The wiring work to this product should be done with the insulation source (<23Vdc) with limited voltage and
current, and a fuse or Class 2 circuit.