![M-tech MT-V82N Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/m-tech/mt-v82n/mt-v82n_user-manual_3102704051.webp)
④
Push
[D•CLR]
to stop the watching.
10.6 Scan resume condition
(USING INITIAL SET MODE)
When a signal is received during scanning, the
scan resume condition determines what action
the transceiver takes. The transceiver has 2 scan
resume conditions available as illustrated below.
Use
SET MODE
to select the one which best suits your
needs.
①
Push
[A•FUNC]
, then push
[8•SET]
to enter
SET MODE
.
②
Push
[▲]
or
[▼]
several times until “SCP” or “SCt”
appears.
③
Rotate
[VOL]
to select the desired scan resume
condition.
• Pause scan:
When receiving a signal, scan
pauses on the signal until it
disappears. Resumes 2 sec.
after the signal disappears.
• Timer scan:
When receiving a signal, scan
pauses on the signal for 5
sec., 10 sec. or 15 sec., then
resumes.
④
Push
[
✱
•ENT ]
(or
[D•CLR]
) to set and exit
SET MODE.
SCAN OPERATION
5 sec.
VFO frequency
Priority channel
Memory
scan
Mch 3
Mch 1
Mch 5
Skip
Mch 199
Mch 6
Mch 2
Mch 4
50 msec.
Pause scan
Timer scan
49