background image

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7775-C  Rev.2  P. 1 / 11

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

High speed DC voltage input module ................................(1)
Mounter slider.....................................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures. 

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVE

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    24V DC rating: 24V ±10%, approx. 40mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• Before you remove the terminal block or mount it, make 

sure to turn off the power supply for safety.

• DO NOT operate the switches on the unit while the power 

is supplied. Be sure to turn off the power supply when 
performing configuration using the switches.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -0 to +55°C 

(32 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Be sure to close the terminal cover to prevent electric 

shock.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

HIGH SPEED DC VOLTAGE INPUT MODULE

(MECHATROLINK-I/II, 8 points, non-isolated)

MODEL

R7G4HML-6-SVF8N

Содержание R7G4HML-6-SVF8N

Страница 1: ...ting marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10 approx 40mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply an...

Страница 2: ...ED ID COLOR FUNCTION PWR Green Turns on when the internal 5V is sup plied normally RUN Green Turns on in normal communications conditions ERR Red blinking in setting error Turns on in no communication...

Страница 3: ...7 COM5 COM6 V0 COM0 COM1 V1 V2 V3 COM2 COM3 COM7 NO ID FUNCTION NO ID FUNCTION 1 COM0 Common 0 10 V0 Voltage Input 0 2 COM1 Common 1 11 V1 Voltage Input 1 3 COM2 Common 2 12 V2 Voltage Input 2 4 COM3...

Страница 4: ...DIN rail 1 2 3 SURFACE MOUNTING 1 Insert the two mounter sliders along the rail on the back of the unit until it clicks once as shown below 1 1 2 Mount the unit with M4 screws referring to MOUNT ING...

Страница 5: ...NOT a protective conductor termi nal 11 2 17 18 9 8 V6 COM6 V7 COM7 12 V2 COM2 V3 COM3 13 4 3 15 V4 COM4 V5 COM5 16 7 6 6 7 24V DC 0V 3 FE 10 V0 COM0 1 INPUT 0 V1 COM1 INPUT 1 INPUT 2 INPUT 3 INPUT 4...

Страница 6: ...f slaves might change depending on the master unit Refer to the manual of the master unit Transmission cycle 0 5 msec 1 msec 1 5 msec 2 msec 4 msec 8 msec Data length 17 bytes 32 bytes selectable Must...

Страница 7: ...MECHATROLINK APPLICATION LAYER COMMAND DESCRIPTIONS The following tables explain Application Layer Commands supported by the R7G4HML Intelligent I O NOP Command 00H Data Format Byte COMMAND RESPONSE...

Страница 8: ...I or binary data 15 0 ID8 ASCII or binary data 16 0 0 17 31 0 0 0 0 Byte 17 through 31 are always 0 in the 32 byte mode These bytes are unavailable for MECHATROLINK I or MECHATROLINK II in the 17 byte...

Страница 9: ...are always 0 in the 32 byte mode These bytes are unavailable for MECHATROLINK I or MECHATROLINK II in the 17 byte mode DATA_RWA Command 50H Data Format MECHATROLINK I MECHATROLINK II in the 17 byte m...

Страница 10: ...H5 data Lower 8 bits 16 0 CH5 IN HI CH5 data Upper 8 bits 17 0 CH6 IN LO CH6 data Lower 8 bits 18 0 CH6 IN HI CH6 data Upper 8 bits 19 0 CH7 IN LO CH7 data Lower 8 bits 20 0 CH7 IN HI CH7 data Upper 8...

Страница 11: ...Status 0 7 Byte16 Byte15 0 7 CH0 Input Range Error 15 115 CH1 Input Range Error 15 115 CH2 Input Range Error 15 115 CH3 Input Range Error 15 115 CH4 Input Range Error 15 115 CH5 Input Range Error 15...

Отзывы: