R3-NM1

P. 7 / 7

EM-8354 Rev.4

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

0

15

Input 1   (Output 1)
Input 2   (Output 2)
Input 3   (Output 3)

     :               :
Input 16 (Output 16)

0 : OFF (open)

1 : ON (close)

 DISCRETE DATA (models: R3-DA16 and DC16)

 MAIN / SUB SWITCHING CONTROL

1)  When the main/sub switching control for both main and sub network is set to ‘0, ’ all contact outputs are off, and analog 

output modules output -115%.

2)  When the main’s setting is switched to ‘1,’ the output modules are in control of the main host device.
3)  When a loss of communication is detected in the main network, the output signal is held for the preset time period. (Timer 

is programmable with the PC Configurator Software, R3CON.)  After the time has been elapsed, the output control is 
switched from the main to the sub network.  Be sure to set an appropriate output signal to the sub network and switch the 
sub’s setting to ‘1’ before such switching occurs.

4)  The output modules’ control does not automatically switched back to the main’s when the main network is restored if the 

main’s setting is ‘0.’  Be sure to switch the setting back to ‘1’ before the communication is restored.

5)  When both the main and the sub network modules are in communication, the output can be switched without delay.

Address : 01025 = 0

Communication Status

Start

Main Lost

Main Restored

Switching by Host

Address : 01025 = 1

R3 main network

(main/sub switching control)

Address : 01025 = 0

Address : 01025 = 1

R3 sub network

(main/sub switching control)

(1)

(2)

(3)

(4)

(5)

Содержание R3-NM1

Страница 1: ...es are present in the air install the unit inside proper housing with sufficient ven tilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical...

Страница 2: ...rom the slot No 1 through 8 Setting for No 9 and later slots is identical to No 8 RUN LED FRONT VIEW SIDE VIEW ERR LED SA1 SA2 1 2 3 4 5 6 Terminal Block Node Address MSD Node Address LSD Transmission...

Страница 3: ...ERNAL DIMENSIONS unit mm inch MODBUS WIRING 1 2 3 4 5 6 130 5 12 27 5 1 08 109 4 29 POSITIONING GUIDE TERMINAL COVER 6 M3 SCREW 6 2 24 TERMINATOR Tx Rx Tx Rx SG Rx Rx HOST PC DA DB DG SLD FG R3 NM1 DA...

Страница 4: ...15 Force Multiple Coils X Digital output from the slave read write 16 Preset Multiple Registers X General purpose register within the slave read write 17 Report Slave ID 18 Program 884 M84 19 Reset Co...

Страница 5: ...7 1072 Data Error Status Input Registers 3X 1 256 I Analog Input 257 768 F Analog Input Holding Registers 4X 1 256 I Analog Output 257 768 F Analog Output I Integer 0 10000 0 100 F Floating 32 bit dat...

Страница 6: ...the data For example 135 4 F is con verted into 135 Minus temperature is converted into negative values represented in 2 s complements ACCUMULATED COUNT DATA 32 bit data models R3 PA2 PA4A WT1 WT4 et...

Страница 7: ...fo m system co jp 0 15 Input 1 Output 1 Input 2 Output 2 Input 3 Output 3 Input 16 Output 16 0 OFF open 1 ON close DISCRETE DATA models R3 DA16 and DC16 MAIN SUB SWITCHING CONTROL 1 When the main sub...

Отзывы: