MODBUS FUNCTION CODES & SUPPORTED CODES

 

DATA & CONTROL FUNCTIONS

 

CODE 

NAME 

R3-NM1

 

01 

Read Coil Status 

Digital output from the slave (read/write)

 

02 

Read Input Status 

Status of digital inputs to the slave (read only)

 

03 

Read Holding Registers 

General purpose register within the slave (read/write)

 

04 

Read Input Registers 

Collected data from the field by the slave (read only)

 

05 

Force Single Coil 

Digital output from the slave (read/write)

 

06 

Preset Single Registers 

General purpose register within the slave (read/write)

 

07 

Read Exception Status

 

08 

Diagnostics 

X

 

09 

Program 484

 

10 

Poll 484

 

11 

Fetch Comm. Event Counter 

Fetch a status word and an event counter

 

12 

Fetch Comm. Event Log 

A status word, an event counter, a message count and a field of event bytes

 

13 

Program Controller

 

14 

Poll Controller

 

15 

Force Multiple Coils 

Digital output from the slave (read/write)

 

16 

Preset Multiple Registers 

General purpose register within the slave (read/write)

 

17 

Report Slave ID

 

18 

Program 884/M84

 

19 

Reset Comm. Link

 

20 

Read General Reference

 

21 

Write General Reference

 

22 

Mask Write 4X Register

 

23 

Read/Write 4X Register

 

24 

Read FIFO Queue

 

EXCEPTION CODES

 

CODE 

NAME 

R3-NM1

 

01 

Illegal Function 

Function code is not allowable for the slave

 

02 

Illegal Data Address 

Address is not available within the slave

 

03 

Illegal Data Value 

Data is not valid for the function

 

04 

Slave Device Failure 

X

 

05 

Acknowledge 

X

 

06 

Slave Device Busy 

X

 

07 

Negative Acknowledge 

X

 

08 

Memory Parity Error

 

DIAGNOSTIC SUBFUNCTIONS

 

CODE 

NAME 

R3-NM1

 

00 

Return Query Data 

Loop back test

 

01 

Restart Comm. Option 

Reset the slave and clear all counters

 

02 

Return Diagnostic Register 

Contents of the diagnostic data (2 bytes)

 

03 

Change ASCII Input Delimiter 

Delimiter character of ASCII message

 

04 

Force Listen Only Mode 

Force the slave into Listen Only Mode

Содержание R3-NM1

Страница 1: ...es are present in the air install the unit inside proper housing with sufficient ven tilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical...

Страница 2: ...rom the slot No 1 through 8 Setting for No 9 and later slots is identical to No 8 RUN LED FRONT VIEW SIDE VIEW ERR LED SA1 SA2 1 2 3 4 5 6 Terminal Block Node Address MSD Node Address LSD Transmission...

Страница 3: ...ERNAL DIMENSIONS unit mm inch MODBUS WIRING 1 2 3 4 5 6 130 5 12 27 5 1 08 109 4 29 POSITIONING GUIDE TERMINAL COVER 6 M3 SCREW 6 2 24 TERMINATOR Tx Rx Tx Rx SG Rx Rx HOST PC DA DB DG SLD FG R3 NM1 DA...

Страница 4: ...15 Force Multiple Coils X Digital output from the slave read write 16 Preset Multiple Registers X General purpose register within the slave read write 17 Report Slave ID 18 Program 884 M84 19 Reset Co...

Страница 5: ...7 1072 Data Error Status Input Registers 3X 1 256 I Analog Input 257 768 F Analog Input Holding Registers 4X 1 256 I Analog Output 257 768 F Analog Output I Integer 0 10000 0 100 F Floating 32 bit dat...

Страница 6: ...the data For example 135 4 F is con verted into 135 Minus temperature is converted into negative values represented in 2 s complements ACCUMULATED COUNT DATA 32 bit data models R3 PA2 PA4A WT1 WT4 et...

Страница 7: ...fo m system co jp 0 15 Input 1 Output 1 Input 2 Output 2 Input 3 Output 3 Input 16 Output 16 0 OFF open 1 ON close DISCRETE DATA models R3 DA16 and DC16 MAIN SUB SWITCHING CONTROL 1 When the main sub...

Отзывы: